Intra-rater repeatability of gait parameters in healthy adults during self-paced treadmill-based virtual reality walking.

Mohammad Al-Amri1,2, Hilal Al Balushi1, Abdulrhman Mashabi1.   

Abstract

Self-paced treadmill walking is becoming increasingly popular for the gait assessment and re-education, in both research and clinical settings. Its day-to-day repeatability is yet to be established. This study scrutinised the test-retest repeatability of key gait parameters, obtained from the Gait Real-time Analysis Interactive Lab (GRAIL) system. Twenty-three male able-bodied adults (age: 34.56 ± 5.12 years) completed two separate gait assessments on the GRAIL system, separated by 5 ± 3 days. Key gait kinematic, kinetic, and spatial-temporal parameters were analysed. The Intraclass-Correlation Coefficients (ICC), Standard Error Measurement (SEM), Minimum Detectable Change (MDC), and the 95% limits of agreements were calculated to evaluate the repeatability of these gait parameters. Day-to-day agreements were excellent (ICCs > 0.87) for spatial-temporal parameters with low MDC and SEM values, <0.153 and <0.055, respectively. The repeatability was higher for joint kinetic than kinematic parameters, as reflected in small values of SEM (<0.13 Nm/kg and <3.4°) and MDC (<0.335 Nm/kg and <9.44°). The obtained values of all parameters fell within the 95% limits of agreement. Our findings demonstrate the repeatability of the GRAIL system available in our laboratory. The SEM and MDC values can be used to assist researchers and clinicians to distinguish 'real' changes in gait performance over time.

Entities:  

Keywords:  GRAIL; Reliability; gait analysis; instrumented treadmill; self-paced walking

Mesh:

Year:  2017        PMID: 29168396     DOI: 10.1080/10255842.2017.1404994

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  3 in total

1.  Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity.

Authors:  Mohammad Al-Amri; Kevin Nicholas; Kate Button; Valerie Sparkes; Liba Sheeran; Jennifer L Davies
Journal:  Sensors (Basel)       Date:  2018-02-28       Impact factor: 3.576

2.  The Coefficient of Variation of Step Time Can Overestimate Gait Abnormality: Test-Retest Reliability of Gait-Related Parameters Obtained with a Tri-Axial Accelerometer in Healthy Subjects.

Authors:  Shunrou Fujiwara; Shinpei Sato; Atsushi Sugawara; Yasumasa Nishikawa; Takahiro Koji; Yukihide Nishimura; Kuniaki Ogasawara
Journal:  Sensors (Basel)       Date:  2020-01-21       Impact factor: 3.576

3.  Gait Analysis in a Box: A System Based on Magnetometer-Free IMUs or Clusters of Optical Markers with Automatic Event Detection.

Authors:  Javier Marín; Teresa Blanco; Juan de la Torre; José J Marín
Journal:  Sensors (Basel)       Date:  2020-06-12       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.