Literature DB >> 2916411

Detection of experimental myocarditis by monoclonal antimyosin antibody, Fab fragment.

S Rezkalla1, R A Kloner, B A Khaw, E Haber, J T Fallon, F E Smith, R Khatib.   

Abstract

The purpose of this study was to determine whether monoclonal antimyosin Fab (antigen binding fragment) was capable of labeling hearts with experimental coxsackievirus myocarditis, and to determine whether Fab could be used for detecting myocardial damage in either early or chronic phases of the disease. Sixty-five, 3-week-old cesarean-derived 1 (CD 1) mice were divided into two groups: group I (noninfected animals) and group II (infected with coxsackievirus B3). Mice from each group were killed on days 7, 17, 30, or 90 of infection. Forty-eight hours before killing, mice were injected with monoclonal I125 antimyosin, Fab (25 microCi/injection) and radioactivity was counted in the heart. Selected heart sections were also examined by autoradiography. Heart radioactivity, count/m/mg (m +/- SEM) on days 7, 17, 30, and 90 of infection was 10.8 +/- 1.7, 21.3 +/- 1.1, 11.2 +/- 3.4, and 12.4 +/- 1.5 for group I, versus 36.7 +/- 8.0 (p less than 0.01), 50.0 +/- 4.5 (p less than 0.001), 33.4 +/- 16.1 (p = NS), and 40.6 +/- 8.5 (p less than 0.01) for group II, respectively. Autoradiography revealed focal uptake within areas of necrotic myocardium. We conclude that I125 Fab may be useful in detecting myocardial damage in the experimental model of murine myocarditis up to day 90 of infection.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2916411     DOI: 10.1016/0002-8703(89)90785-0

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  4 in total

Review 1.  Clinical role of indium-111 antimyosin imaging.

Authors:  S Bhattacharya; A Lahiri
Journal:  Eur J Nucl Med       Date:  1991

2.  Myocarditis--a controversial disease.

Authors:  N S Peters; P A Poole-Wilson
Journal:  J R Soc Med       Date:  1991-01       Impact factor: 5.344

Review 3.  Scintigraphic detection of inflammatory heart disease.

Authors:  A J Morguet; D L Munz; H Kreuzer; D Emrich
Journal:  Eur J Nucl Med       Date:  1994-07

4.  Technetium-99m antimyosin antibody (3-48) myocardial imaging: human biodistribution, safety and clinical results in detection of acute myocardial infarction.

Authors:  R Taillefer; L Boucher; R Lambert; J Grégoire; D C Phaneuf; H Sikorsa
Journal:  Eur J Nucl Med       Date:  1995-05
  4 in total