Literature DB >> 29160400

Microtensile Bond Strength of Adhesive Systems in Different Dentin Regions on a Class II Cavity Configuration.

Mário Alexandre Coelho Sinhoreti1, Eveline Freitas Soares1, Gabriel Flores Abuna1, Lourenço Correr1, Jean-François Roulet2, Saulo Geraldeli2.   

Abstract

The aim of this study was to evaluate microtensile bond strength (µTBS) of self-etch and etch-and-rinse adhesives systems compared in different dentin regions (central-CD or proximal-PD) in a class II cavity configuration. A class II (mesial-oclusal-distal) cavity configuration was simulated on 20 extracted human third-molars (4 mm wide/3 mm deep). Etch-and-rinse adhesive (Scotchbond Multi Purpose, n=5, SBMP and Optibond FL, n=5, OPFL) and self-etch adhesives (Clearfil SE Bond, n=5, CSE and Optibond XTR, n=5, OPXTR) were applied. Class II restorations were performed by incremental technique and photo-activated (Bluephase/G2). Samples were sectioned to beam shape (1 mm² cross-section), placed on Geraldeli's device for µTBS test (0.5 mm/min cross-head speed). Fracture patterns were analyzed on stereomicroscope and classified as cohesive-resin, adhesive, mixed/resin or mixed/dentin. Samples (n=4) were prepared for scanning electron microscope observation. Data were submitted to one-way ANOVA with Split-Plot arrangement and Tukey's test (α=0.05). There were no statistically significant differences among SBMP, OPFL, CSE and OPXTR on CD (p>0.05). However, on PD for SBMP and OPFL, µTBS values were significantly lower compared to CSE and OPXTR (p<0.05). In all groups, mixed failure pattern was more frequently observed, except for SBMP/CD (adhesive). In class II type cavity configuration, PD location negatively influenced bond strength of etch-and-rinse adhesive systems. Opposite to self-etching adhesives, which presented higher bond strength values compared to etch-and-rinse adhesives in PD.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29160400     DOI: 10.1590/0103-6440201701541

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  2 in total

Review 1.  Assessment of Bonding Effectiveness of Adhesive Materials to Tooth Structure using Bond Strength Test Methods: A Review of Literature.

Authors:  Aminah M El Mourad
Journal:  Open Dent J       Date:  2018-09-28

2.  Influence of two carbodiimides on the bond strength of universal adhesives to dentin.

Authors:  Ana Beatriz Franco Fernandes; Rafael Coutinho Silva; Matheus André Müller; Leonardo Fernandes da Cunha; Gisele Maria Correr; Carla Castiglia Gonzaga
Journal:  Odontology       Date:  2021-07-19       Impact factor: 2.634

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.