Literature DB >> 29160399

Marginal and Internal Adaptation of Zirconia Crowns: A Comparative Study of Assessment Methods.

Rafael Schlögel Cunali1, Rafaella Caramori Saab1, Gisele Maria Correr1, Leonardo Fernandes da Cunha1, Bárbara Pick Ornaghi1, André V Ritter2, Carla Castiglia Gonzaga1.   

Abstract

Marginal and internal adaptation is critical for the success of indirect restorations. New imaging systems make it possible to evaluate these parameters with precision and non-destructively. This study evaluated the marginal and internal adaptation of zirconia copings fabricated with two different systems using both silicone replica and microcomputed tomography (micro-CT) assessment methods. A metal master model, representing a preparation for an all-ceramic full crown, was digitally scanned and polycrystalline zirconia copings were fabricated with either Ceramill Zi (Amann-Girrbach) or inCoris Zi (Dentslpy-Sirona), n=10. For each coping, marginal and internal gaps were evaluated by silicone replica and micro-CT assessment methods. Four assessment points of each replica cross-section and micro-CT image were evaluated using imaging software: marginal gap (MG), axial wall (AW), axio-occlusal angle (AO) and mid-occlusal wall (MO). Data were statistically analyzed by factorial ANOVA and Tukey test (a=0.05). There was no statistically significant difference between the methods for MG and AW. For AO, there were significant differences between methods for Amann copings, while for Dentsply-Sirona copings similar values were observed. For MO, both methods presented statistically significant differences. A positive correlation was observed determined by the two assessment methods for MG values. In conclusion, the assessment method influenced the evaluation of marginal and internal adaptation of zirconia copings. Micro-CT showed lower marginal and internal gap values when compared to the silicone replica technique, although the difference was not always statistically significant. Marginal gap and axial wall assessment points showed the lower gap values, regardless of ceramic system and assessment method used.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29160399     DOI: 10.1590/0103-6440201601531

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  4 in total

1.  Internal fit evaluation of indirect restorations fabricated from CAD/CAM composite blocks versus ceramic blocks in badly broken teeth using cone beam CT (CBCT): double-blinded randomized clinical trial.

Authors:  Shereen Hafez Ibrahim; Haitham Amr; Ahmed A Hassan; Ahmed Elzohairy
Journal:  Heliyon       Date:  2022-05-19

2.  Microcomputed tomography a noninvasive method to evaluate the fit of a restoration as compared to conventional replica technique.

Authors:  Sabita M Ram; Nishita Narendra Ranadive; Jyoti B Nadgere
Journal:  J Indian Prosthodont Soc       Date:  2019 Jul-Sep

3.  In vitro comparison of marginal and internal fit between stainless steel crowns and esthetic crowns of primary molars using different luting cements.

Authors:  Sanaa Najeh Al-Haj Ali
Journal:  Dent Res J (Isfahan)       Date:  2019-11-12

Review 4.  A systematic review on the accuracy of zirconia crowns and fixed dental prostheses.

Authors:  Per Svanborg
Journal:  Biomater Investig Dent       Date:  2020-01-07
  4 in total