Literature DB >> 29159513

Molybdenum coated SU-8 microneedle electrodes for transcutaneous electrical nerve stimulation.

Ramin Soltanzadeh1, Elnaz Afsharipour2, Cyrus Shafai2, Neda Anssari3, Behzad Mansouri3, Zahra Moussavi4.   

Abstract

Electrophysiological devices are connected to the body through electrodes. In some applications, such as nerve stimulation, it is needed to minimally pierce the skin and reach the underneath layers to bypass the impedance of the first layer called stratum corneum. In this study, we have designed and fabricated surface microneedle electrodes for applications such as electrical peripheral nerve stimulation. We used molybdenum for microneedle fabrication, which is a biocompatible metal; it was used for the conductive layer of the needle array. To evaluate the performance of the fabricated electrodes, they were compared with the conventional surface electrodes in nerve conduction velocity experiment. The recorded signals showed a much lower contact resistance and higher bandwidth in low frequencies for the fabricated microneedle electrodes compared to those of the conventional electrodes. These results indicate the electrode-tissue interface capacitance and charge transfer resistance have been increased in our designed electrodes, while the contact resistance decreased. These changes will lead to less harmful Faradaic current passing through the tissue during stimulation in different frequencies. We also compared the designed microneedle electrodes with conventional ones by a 3-dimensional finite element simulation. The results demonstrated that the current density in the deep layers of the skin and the directivity toward a target nerve for microneedle electrodes were much more than those for the conventional ones. Therefore, the designed electrodes are much more efficient than the conventional electrodes for superficial transcutaneous nerve stimulation purposes.

Entities:  

Keywords:  Electrode/tissue interface; Electrophysiological devices; Microneedle patches; Peripheral nerve stimulation

Mesh:

Substances:

Year:  2017        PMID: 29159513     DOI: 10.1007/s10544-017-0241-9

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  2 in total

1.  High-Performance Flexible Microneedle Array as a Low-Impedance Surface Biopotential Dry Electrode for Wearable Electrophysiological Recording and Polysomnography.

Authors:  Junshi Li; Yundong Ma; Dong Huang; Zhongyan Wang; Zhitong Zhang; Yingjie Ren; Mengyue Hong; Yufeng Chen; Tingyu Li; Xiaoyi Shi; Lu Cao; Jiayan Zhang; Bingli Jiao; Junhua Liu; Hongqiang Sun; Zhihong Li
Journal:  Nanomicro Lett       Date:  2022-06-14

2.  Robust, Long-Term, and Exceptionally Sensitive Microneedle-Based Bioimpedance Sensor for Precision Farming.

Authors:  Abdullah Bukhamsin; Khalil Moussi; Ran Tao; Gilles Lubineau; Ikram Blilou; Khaled Nabil Salama; Jürgen Kosel
Journal:  Adv Sci (Weinh)       Date:  2021-06-17       Impact factor: 16.806

  2 in total