Literature DB >> 29159271

Is there any tip that makes performing EUS-guided drainage easier and safer?

Woo Hyun Paik1, Do Hyun Park2.   

Abstract

Entities:  

Year:  2017        PMID: 29159271      PMCID: PMC5633404          DOI: 10.1055/s-0043-112495

Source DB:  PubMed          Journal:  Endosc Int Open        ISSN: 2196-9736


× No keyword cloud information.
Endoscopic ultrasound (EUS)-guided drainage is evolving and no standardized technique for it has been established yet. Availability of dedicated devices and accessories also are lacking. Anderloni et al. described a new technique of stent deployment named Intra Channel Stent Release Technique (ICSRT) in EUS-guided drainage 1 , which is summarized as follows: deployment of the proximal part of the stent within the working channel of the echoendoscope and then gentle withdrawal of the scope. As the authors has emphasized, the core of this technique is maintaining stable and secure positioning of the scope during the procedure, thus decreasing the chance of failure. We totally agree, however, in 2017 we introduced a similar technique called the “modified stent deployment maneuver” 2 . In our previous study about EUS-guided hepaticogastrostomy, to stabilize positioning/attachment of the echoendoscope in the high body of the stomach or the cardia during stent placement, we deployed the front half of the dual-flap metal stent, and next the remainder of the stent within the channel of echoendoscope, and then gently pulled out the echoendoscope, leaving the stent. Because stabilization of the scope is most difficult during hepaticogastrostomy, we introduced this technique with a conventional stent deployment system during EUS-guided hepaticogastrostomy. The concept of our modified stent deployment maneuver and intra-channel stent release technique (ICSRT) is the same, the only difference between the 2 techniques being that ICSRT is performed under complete EUS control using a novel dedicated EUS-guided drainage device (Hot AXIOS TM , Boston Scientific Corp., Malborough, MA, USA). However, fluoroscopic guidance is mandatory during hepaticogastrostomy. Even during EUS-guided choledochoduodenostomy, we recommend doing the procedure under fluoroscopic guidance because it is not possible to anticipate what problems may develop during EUS-guided drainage. Finally, according to this study, the role of black marker in the catheter for endoscopic deployment of the proximal flange in the AXIOS stent is questionable. Given the high cost of the AXIOS stent with dedicated endoscopic deployment system, a dedicated lumen-apposing stent with conventional deployment system may be more attractive. EUS-guided drainage is a challenging procedure and formal training dedicated to EUS-guided drainage is difficult. To develop and establish a standardized protocol for EUS-guided drainage, sharing technical tips and information development of dedicated devices is important.
  2 in total

1.  Simplified fistula dilation technique and modified stent deployment maneuver for EUS-guided hepaticogastrostomy.

Authors:  Woo Hyun Paik; Do Hyun Park; Jun-Ho Choi; Joon Hyuk Choi; Sang Soo Lee; Dong Wan Seo; Sung Koo Lee; Myung-Hwan Kim; Jung Bok Lee
Journal:  World J Gastroenterol       Date:  2014-05-07       Impact factor: 5.742

2.  Intra-channel stent release technique for fluoroless endoscopic ultrasound-guided lumen-apposing metal stent placement: changing the paradigm.

Authors:  Andrea Anderloni; Fabia Attili; Silvia Carrara; Domenico Galasso; Milena Di Leo; Guido Costamagna; Alessandro Repici; Rastislav Kunda; Alberto Larghi
Journal:  Endosc Int Open       Date:  2017-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.