Literature DB >> 29155937

Nanoparticle-based lateral flow biosensor combined with multiple cross displacement amplification for rapid, visual and sensitive detection of Vibrio cholerae.

Yi Wang1, Hui Li2, Yan Wang1, Lu Zhang1, Jingyun Zhang1, Jianguo Xu1, Changyun Ye1.   

Abstract

Vibrio cholerae is an important human pathogen that is responsible for cholera, a severe acute watery diarrhea. In the current study, a multiple cross displacement amplification (MCDA) coupled with amplicon detection by chromatographic lateral flow biosensor (LFB) method (MCDA-LFB) was successfully established and evaluated for the identification of V. cholerae. A set of 10 primers was designed specifically to recognize 10 different regions of the V. cholerae-specific gene ompW. The optimized time and temperature conditions for the MCDA were 30 min and 63°C, respectively. The MCDA-LFB assay correctly identified 31 strains of V. cholerae but did not detect 13 non-cholerae Vibrio strains and 30 non-Vibrio strains. The sensitivity of MCDA-LFB for target pathogen detection in pure culture was 10 fg per reaction. In the case of spiked shrimp samples without enrichment, the limit of detection was 4.1 CFUs per reaction or equivalent to 4.1 × 102 CFU g-1. The whole process, including shrimp homogenates processing (30 min), MCDA reaction (30 min) and results reporting (2 min), could be finished within 65 min. These results show that this assay is suitable for the rapid, sensitive and specific detection of V. cholerae in food, environmental and clinical samples. © FEMS 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

Entities:  

Keywords:  MCDA-LFB; Vibro cholerae; lateral flow biosensor; limit of detection; multiple cross displacement amplification

Mesh:

Substances:

Year:  2017        PMID: 29155937     DOI: 10.1093/femsle/fnx234

Source DB:  PubMed          Journal:  FEMS Microbiol Lett        ISSN: 0378-1097            Impact factor:   2.742


  2 in total

1.  Development of a multiple cross displacement amplification combined with nanoparticles-based biosensor assay to detect Neisseria meningitidis.

Authors:  Shijun Li; Chunting Liu; Ying Liu; Qing Ma; Yue Wang; Yi Wang
Journal:  Infect Drug Resist       Date:  2019-07-15       Impact factor: 4.003

2.  A Novel Detection of Enterococcus faecalis Using Multiple Cross Displacement Amplification Linked with Gold Nanoparticle Lateral Flow Biosensor.

Authors:  Xu Chen; Kai Ma; Xu Yi; Ziyu Xiao; Lijuan Xiong; Yu Wang; Shijun Li
Journal:  Infect Drug Resist       Date:  2019-12-04       Impact factor: 4.003

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.