Literature DB >> 29153478

Reliability of upper limb and trunk joint angles in healthy adults during activities of daily living.

Susannah M Engdahl1, Deanna H Gates2.   

Abstract

Assessments of upper limb performance should require participants to perform tasks that challenge the limits of their ability. In order to select appropriate tasks, it is important to know which joints are used to perform the movement and how reliably those movements can be measured. The purpose of this work was to quantify the reliability of upper limb and trunk joint angles in healthy adults during common activities of daily living (ADLs). Nineteen participants performed six ADLs with the right arm (applying deodorant, turning a doorknob, answering a desk telephone, placing a pushpin in a bulletin board, wiping a plate with a towel, and pouring water from a pitcher) during two separate sessions. Within- and between-session reliability was quantified using intraclass correlation coefficients (ICCs) and minimum detectable change values (MDCs). Reliability was generally better within-session than between-session. The ICCs exceeded 0.75 for 88% of the joint angles and exceeded 0.90 for 32% of the angles. All MDCs were less than 25° and 61% were also less than 10°. The MDCs represented a larger percent of the average angles for the trunk (61%) and wrist (62%) compared to the shoulder (18%) and elbow (26%). Although these results show that most angles can be measured reliably for these six ADLs, reliability varied considerably between joints. It is therefore important to select tasks for assessing of upper limb performance based on which specific joints need to be evaluated.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Activities of daily living; Kinematics; Repeatability; Test-retest reliability; Upper limb

Mesh:

Year:  2017        PMID: 29153478      PMCID: PMC5809188          DOI: 10.1016/j.gaitpost.2017.11.001

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  28 in total

Review 1.  Movement biomechanics goes upwards: from the leg to the arm.

Authors:  G Rau; C Disselhorst-Klug; R Schmidt
Journal:  J Biomech       Date:  2000-10       Impact factor: 2.712

2.  The globe system: an unambiguous description of shoulder positions in daily life movements.

Authors:  Caroline A M Doorenbosch; Jaap Harlaar; DirkJan H E J Veeger
Journal:  J Rehabil Res Dev       Date:  2003 Mar-Apr

3.  Reliability and Minimal Detectible Change values for gait kinematics and kinetics in healthy adults.

Authors:  Jason M Wilken; Kelly M Rodriguez; Melissa Brawner; Benjamin J Darter
Journal:  Gait Posture       Date:  2011-10-29       Impact factor: 2.840

4.  Validity and reliability of upper extremity three-dimensional kinematics during a typing task.

Authors:  Yafa Levanon; Amit Gefen; Yehuda Lerman; Uri Givon; Navah Z Ratzon
Journal:  Gait Posture       Date:  2010-08-03       Impact factor: 2.840

Review 5.  Understanding the minimum clinically important difference: a review of concepts and methods.

Authors:  Anne G Copay; Brian R Subach; Steven D Glassman; David W Polly; Thomas C Schuler
Journal:  Spine J       Date:  2007-04-02       Impact factor: 4.166

6.  Compensatory strategies for reaching in stroke.

Authors:  M C Cirstea; M F Levin
Journal:  Brain       Date:  2000-05       Impact factor: 13.501

7.  Test-retest reliability, validity, and sensitivity of the Chedoke arm and hand activity inventory: a new measure of upper-limb function for survivors of stroke.

Authors:  Susan R Barreca; Paul W Stratford; Cynthia L Lambert; Lisa M Masters; David L Streiner
Journal:  Arch Phys Med Rehabil       Date:  2005-08       Impact factor: 3.966

8.  Ranges of active joint motion for the shoulder, elbow, and wrist in healthy adults.

Authors:  Junya Aizawa; Tadashi Masuda; Kashitaro Hyodo; Tetsuya Jinno; Kazuyoshi Yagishita; Koji Nakamaru; Takayuki Koyama; Sadao Morita
Journal:  Disabil Rehabil       Date:  2013-08       Impact factor: 3.033

9.  Reproducibility and minimal detectable change of three-dimensional kinematic analysis of reaching tasks in people with hemiparesis after stroke.

Authors:  Joanne M Wagner; Jennifer A Rhodes; Carolynn Patten
Journal:  Phys Ther       Date:  2008-03-06

10.  The case for using the repeatability coefficient when calculating test-retest reliability.

Authors:  Sharmila Vaz; Torbjörn Falkmer; Anne Elizabeth Passmore; Richard Parsons; Pantelis Andreou
Journal:  PLoS One       Date:  2013-09-09       Impact factor: 3.240

View more
  1 in total

1.  Quantitative Eye Gaze and Movement Differences in Visuomotor Adaptations to Varying Task Demands Among Upper-Extremity Prosthesis Users.

Authors:  Jacqueline S Hebert; Quinn A Boser; Aïda M Valevicius; Hiroki Tanikawa; Ewen B Lavoie; Albert H Vette; Patrick M Pilarski; Craig S Chapman
Journal:  JAMA Netw Open       Date:  2019-09-04
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.