Literature DB >> 29153087

A fluorescence aptasensor based on two-dimensional sheet metal-organic frameworks for monitoring adenosine triphosphate.

Xiao-Man Hai1, Nan Li1, Ke Wang1, Zhi-Qi Zhang1, Jing Zhang1, Fu-Quan Dang2.   

Abstract

In the present study, a facile fluorescence aptasensor based on two-dimensional sheet metal-organic frameworks of N,N-bis(2-hydroxyethyl)dithiooxamidato copper(II) (H2dtoaCu) was developed for the sensitive detection of adenosine triphosphate (ATP). The sensing mechanism was based on the noncovalent interaction between FAM-labeled (fluorescein amidite) ATP aptamers and H2dtoaCu. In the absence of ATP, the FAM-labeled aptamer readily adsorbs onto H2dtoaCu, mainly via π-π stacking and hydrogen bond interactions between the nucleotide bases and the H2dtoaCu surface, leading to the reduction of fluorescence intensity of the FAM by photoinduced electron transfer (PET). In the presence of ATP, the FAM-labeled aptamer specifically forms ATP-binding aptamer complexes which exhibit only weak adsorption on the H2dtoaCu surface. Thus, the fluorescence of the FAM-labeled ATP aptamer remained largely unchanged. The fluorescence aptasensor exhibited a good linear relationship between the fluorescence intensity and the logarithm concentration of ATP over a range of 25-400 nM, with a detection limit of 8.19 nM (3S/N). ATP analogs such as guanosine triphosphate, uridine triphosphate, and cytidine triphosphate have negligible effect on the aptasensor performance due to the high selectivity of the ATP aptamer to its target, showing promising potential in real sample analysis.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Adenosine triphosphate; Aptamer; Fluorescence; H(2)dtoaCu

Mesh:

Substances:

Year:  2017        PMID: 29153087     DOI: 10.1016/j.aca.2017.10.028

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  8 in total

1.  Signal amplification by strand displacement in a carbon dot based fluorometric assay for ATP.

Authors:  Jieping Luo; Xin Shen; Bingzhi Li; Xiaoyun Li; Xuemin Zhou
Journal:  Mikrochim Acta       Date:  2018-07-28       Impact factor: 5.833

2.  A switchable and signal-amplified aptasensor based on metal organic frameworks as the quencher for turn-on detection of T-2 mycotoxin.

Authors:  Xinliu Tan; Weidao Yu; Yuwen Wang; Ping Song; Qing Xu; Dengming Ming; Yaqiong Yang
Journal:  Anal Bioanal Chem       Date:  2021-08-24       Impact factor: 4.142

Review 3.  Aptamer-functionalized metal-organic frameworks (MOFs) for biosensing.

Authors:  Mengzhen Lv; Wan Zhou; Hamed Tavakoli; Cynthia Bautista; Jianfei Xia; Zonghua Wang; XiuJun Li
Journal:  Biosens Bioelectron       Date:  2020-12-30       Impact factor: 10.618

4.  A Label-Free Fluorescent DNA Machine for Sensitive Cyclic Amplification Detection of ATP.

Authors:  Jingjing Zhang; Jialun Han; Shehong Feng; Chaoqun Niu; Chen Liu; Jie Du; Yong Chen
Journal:  Materials (Basel)       Date:  2018-11-29       Impact factor: 3.623

5.  Label-Free Fluorescent Aptasensor for Small Targets via Displacement of Groove Bound Curcumin Molecules.

Authors:  Baraa J Alyamani; Omar A Alsager; Mohammed Zourob
Journal:  Sensors (Basel)       Date:  2019-09-26       Impact factor: 3.576

6.  Challenges and stepwise fit-for-purpose optimization for bioanalyses of remdesivir metabolites nucleotide monophosphate and triphosphate in mouse tissues using LC-MS/MS.

Authors:  Wenjuan Hu; Lu Chang; Changqiang Ke; Yuanchao Xie; Jingshan Shen; Bo Tan; Jia Liu
Journal:  J Pharm Biomed Anal       Date:  2020-11-30       Impact factor: 3.935

7.  Correction: A fluorescent biosensor for cardiac biomarker myoglobin detection based on carbon dots and deoxyribonuclease I-aided target recycling signal amplification.

Authors:  Jishun Chen; Fengying Ran; Qinhua Chen; Dan Luo; Weidong Ma; Tuo Han; Ceming Wang; Congxia Wang
Journal:  RSC Adv       Date:  2022-04-27       Impact factor: 4.036

8.  A Label-Free Fluorescent AND Logic Gate Aptasensor for Sensitive ATP Detection.

Authors:  Jingjing Zhang; Chunzheng Yang; Chaoqun Niu; Chen Liu; Xuepin Cai; Jie Du; Yong Chen
Journal:  Sensors (Basel)       Date:  2018-09-29       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.