Use of biofeedback in weaning paralyzed patients from respirators.

J A Corson, J L Grant, D P Moulton, R L Green, P T Dunkel.   

Abstract

Two paralyzed patients who were being treated with mechanical respirators and in whom weaning with intermittent mandatory ventilation failed were treated with regular sessions of biofeedback. Their respiratory volumes were displayed to them on oscilloscopes at bedside. A plastic (Plexiglas) template was placed on the face of the oscilloscope with two horizontal strips of adhesive tape affixed to it; the patient had to achieve a certain tidal volume (TV) to push the tracing outside the space between the horizontal lines. During each session the highest TV achieved determined the target TV to be maintained during the next session. The application of treatment coincided with improved ventilation; both patients were eventually weaned.

Entities:  

Mesh:

Year:  1979        PMID: 291505     DOI: 10.1378/chest.76.5.543

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  1 in total

1.  Development of new measurement system of thoracic excursion with biofeedback: reliability and validity.

Authors:  Yukiko Nishigaki; Hiroko Mizuguchi; Eriko Takeda; Tomokazu Koike; Takeshi Ando; Kazuya Kawamura; Takuro Shimbo; Hidetoshi Ishikawa; Masashi Fujimoto; Ikuko Saotome; Reiko Odo; Kazuko Omoda; Shohei Yamashita; Tomoko Yamada; Toshihito Omi; Yuya Matsushita; Manami Takeda; Sawako Sekiguchi; Saki Tanaka; Masakatsu Fujie; Haruhi Inokuchi; Junko Fujitani
Journal:  J Neuroeng Rehabil       Date:  2013-05-20       Impact factor: 4.262