Literature DB >> 29149956

Comparison Between Total IgG, C1q, and C3d Single Antigen Bead Assays in Detecting Class I Complement-Binding Anti-HLA Antibodies.

M A Moreno Gonzales1, D G Mitema2, B H Smith3, C A Schinstock4, M D Stegall5, L L Wakefield6, N A Henderson6, S R DeGoey6, J D Kreuter6, M J Gandhi7.   

Abstract

BACKGROUND: Complement-binding donor-specific antibodies (DSAs) are associated with antibody-mediated rejection and allograft loss. Novel single antigen bead (SAB) assays-that is, complement component 1q (C1q) and complement component 3d (C3d) assays-have been developed to specifically detect complement-binding DSA, but it remains unclear whether these assays have an improved ability to detect complement-binding DSA as compared with using the total IgG SAB assay with a high mean fluorescence intensity (MFI) cutoff. The aim of this study was to compare the ability of the total IgG, C1q, and C3d SAB assays in detecting complement-binding anti-HLA antibodies.
METHODS: Twenty sera known to have complement-binding anti-HLA antibodies (serologic class I HLA typing by complement-dependent cytotoxicity method) were tested with 3 different SAB assays: total IgG (undiluted and 1:8 dilution), C1q, and C3d. Serologic anti-HLA specificities were compared with those obtained by IgG, C1q, and C3d SAB assays.
RESULTS: IgG SAB was more sensitive in detecting complement-binding antibodies (sensitivity 24 of 24 = 1, odds ratio infinity). Pearson correlation showed the association between (1) C1q and IgG SAB assays (cutoff C1q SAB 1000 MFI, cutoff IgG SAB 5000 MFI: r = 0.347, P < .0001) and (2) C3d and IgG SAB assays (cutoff 500 MFI C3d SAB, 5000 MFI for IgG SAB: r = -0.173, P = .279).
CONCLUSIONS: For class I anti-HLA antibodies, IgG SAB (cutoff MFI > 5000) was more sensitive in detecting complement-binding antibodies when compared with C1q and C3d SAB assays.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29149956     DOI: 10.1016/j.transproceed.2017.09.040

Source DB:  PubMed          Journal:  Transplant Proc        ISSN: 0041-1345            Impact factor:   1.066


  2 in total

Review 1.  Antibody-mediated complement activation in pathology and protection.

Authors:  Benjamin S Goldberg; Margaret E Ackerman
Journal:  Immunol Cell Biol       Date:  2020-04-06       Impact factor: 5.126

2.  Circulating B Cells With Memory and Antibody-Secreting Phenotypes Are Detectable in Pediatric Kidney Transplant Recipients Before the Development of Antibody-Mediated Rejection.

Authors:  Clara Fischman; Miguel Fribourg; Ginevri Fabrizio; Michela Cioni; Patrizia Comoli; Arcangelo Nocera; Massimo Cardillo; Chiara Cantarelli; Lorenzo Gallon; Astgik Petrosyan; Stefano Da Sacco; Laura Perin; Paolo Cravedi
Journal:  Transplant Direct       Date:  2019-08-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.