Literature DB >> 29148004

Cephalad dislocation of PICCs under different upper limb positions: influence of age, gender, BMI, number of lumens.

Chie-Hee Cho1, Peter Schlattmann2, Sebastian Nagel1, Nina Schmittbuttner1, Frederic Hartung1, Ulf K Teichgraber1.   

Abstract

PURPOSE: To evaluate parameters that influence the amount of movement of peripherally inserted central catheter (PICC) tips regarding upper limb movement.
METHODS: In a prospective 12-month observational study, 200 PICCs were implanted in 162 patients (mean age 56.8 ± 15.2 years) by interventional radiologists into the basilic vein of the mid-aspect of the upper arm. Three PICC tip positions were documented with a chest x-ray: patient supine with an abducted (90°), an adducted arm, and in an upright position with an adducted arm. Multivariable analyses were performed, based on the three positions: body mass index (BMI), number of lumens, age, gender, side of the implantation, and brand.
RESULTS: Up to 88% of the PICCs dislocated in a mean of 19 mm cephalad when the patient was positioned from a supine in an upright position. The greatest influence upon dislocation was the position change from supine to upright. The side of the implanted PICC (left vs. right) had no influence.
CONCLUSIONS: Cephalad dislocations of mean 19 mm regularly occur in the upright position induced by gravity. This needs to be taken in account and the PICC should be safely positioned one vertebra lower in the superior vena cava superior with a last confirmation of the PICC placement in an upright position.

Entities:  

Keywords:  Dislocation; Malpositioning; PICC

Mesh:

Year:  2018        PMID: 29148004     DOI: 10.5301/jva.5000809

Source DB:  PubMed          Journal:  J Vasc Access        ISSN: 1129-7298            Impact factor:   2.283


  4 in total

1.  Magnetic Tracking and Electrocardiography-Guided Tip Confirmation System Versus Fluoroscopy for Placement of Peripherally Inserted Central Catheters: A Randomized, Noninferiority Comparison.

Authors:  V Mack; D Nißler; D Kasikci; A Malouhi; R Aschenbach; U Teichgräber
Journal:  Cardiovasc Intervent Radiol       Date:  2020-06-17       Impact factor: 2.740

2.  Peripherally inserted central venous catheter (PICC) in outpatient and inpatient oncological treatment.

Authors:  Dorothea Mielke; Andrea Wittig; Ulf Teichgräber
Journal:  Support Care Cancer       Date:  2020-01-22       Impact factor: 3.603

3.  Influence of guide wire removal on tip location in peripherally inserted central catheters (PICCs): a retrospective cross-sectional study.

Authors:  Dan Wang; Fangfang Niu; Huining Gao; Mingkai Yu; Yuhang Li; Liqun Xu; Huizhi Cao; Lili Wang; Jinhua Liu; Xue Ding; Ying Wang; Chen Yu; Huiyan Li; Kaijiang Yu; Changsong Wang
Journal:  BMJ Open       Date:  2019-10-31       Impact factor: 2.692

4.  Intracavitary electrocardiography for femorally inserted central catheter tip location in adult patients.

Authors:  YingFang Duan; XiaoYan Hu; YuXin Zhu; Xi Zhao; XinXin Yin; HaiMan Zhang; Yu Wang
Journal:  Ann Noninvasive Electrocardiol       Date:  2021-12-24       Impact factor: 1.468

  4 in total