Literature DB >> 29145735

Evaluation of Performance of Laboratories and Manufacturers Within the Framework of the IFCC model for Quality Targets of HbA1c.

Cas Weykamp1,2, Carla Siebelder1,2.   

Abstract

HbA1c is a key parameter in diabetes management. For years the test has been used exclusively for monitoring of long-term diabetic control. However, due to improvement of the performance, HbA1c is considered more and more for diagnosis and screening. With this new application, quality demands further increase. A task force of the International Federation of Clinical Chemistry and Laboratory Medicine developed a model to set and evaluate quality targets for HbA1c. The model is based on the concept of total error and takes into account the major sources of analytical errors in the medical laboratory: bias and imprecision. Performance criteria are derived from sigma-metrics and biological variation. This review shows 2 examples of the application of the model: at the level of single laboratories, and at the level of a group of laboratories. In the first example data of 125 individual laboratories of a recent external quality assessment program in the Netherlands are evaluated. Differences between laboratories as well as their relation to method principles are shown. The second example uses recent and 3-year-old data of the proficiency test of the College of American Pathologists. The differences in performance between 26 manufacturer-related groups of laboratories are shown. Over time these differences are quite consistent although some manufacturers improved substantially either by better standardization or by replacing a test. The IFCC model serves all who are involved in HbA1c testing in the ongoing process of better performance and better patient care.

Entities:  

Keywords:  HbA1c; diabetes; diagnosis; monitoring; performance; quality targets

Mesh:

Substances:

Year:  2017        PMID: 29145735      PMCID: PMC6134299          DOI: 10.1177/1932296817741320

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  13 in total

1.  IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study.

Authors:  Wieland Hoelzel; Cas Weykamp; Jan-Olof Jeppsson; Kor Miedema; John R Barr; Ian Goodall; Tadao Hoshino; W Garry John; Uwe Kobold; Randie Little; Andrea Mosca; Pierluigi Mauri; Rita Paroni; Fransiscus Susanto; Izumu Takei; Linda Thienpont; Masao Umemoto; Hsiao-Mei Wiedmeyer
Journal:  Clin Chem       Date:  2004-01       Impact factor: 8.327

2.  Standards of medical care in diabetes--2011.

Authors: 
Journal:  Diabetes Care       Date:  2011-01       Impact factor: 19.112

3.  The analytical goals for hemoglobin A(1c) measurement in IFCC units and National Glycohemoglobin Standardization Program Units are different.

Authors:  Cas W Weykamp; Andrea Mosca; Philippe Gillery; Mauro Panteghini
Journal:  Clin Chem       Date:  2011-05-13       Impact factor: 8.327

4.  Proposals for setting generally applicable quality goals solely based on biology.

Authors:  C G Fraser; P Hyltoft Petersen; J C Libeer; C Ricos
Journal:  Ann Clin Biochem       Date:  1997-01       Impact factor: 2.057

5.  Defining acceptable limits for the metrological traceability of specific measurands.

Authors:  Renze Bais; Dave Armbruster; Rob T P Jansen; George Klee; Mauro Panteghini; Joseph Passarelli; Ken A Sikaris
Journal:  Clin Chem Lab Med       Date:  2013-05       Impact factor: 3.694

6.  Criteria for judging precision and accuracy in method development and evaluation.

Authors:  J O Westgard; R N Carey; S Wold
Journal:  Clin Chem       Date:  1974-07       Impact factor: 8.327

7.  International Expert Committee report on the role of the A1C assay in the diagnosis of diabetes.

Authors: 
Journal:  Diabetes Care       Date:  2009-06-05       Impact factor: 17.152

8.  Use of HbA1c in the diagnosis of diabetes mellitus in the UK. The implementation of World Health Organization guidance 2011.

Authors:  W G John
Journal:  Diabet Med       Date:  2012-11       Impact factor: 4.359

9.  Investigation of 2 models to set and evaluate quality targets for hb a1c: biological variation and sigma-metrics.

Authors:  Cas Weykamp; Garry John; Philippe Gillery; Emma English; Linong Ji; Erna Lenters-Westra; Randie R Little; Gojka Roglic; David B Sacks; Izumi Takei
Journal:  Clin Chem       Date:  2015-03-03       Impact factor: 8.327

10.  Report of the committee on the classification and diagnostic criteria of diabetes mellitus.

Authors:  Yutaka Seino; Kishio Nanjo; Naoko Tajima; Takashi Kadowaki; Atsunori Kashiwagi; Eiichi Araki; Chikako Ito; Nobuya Inagaki; Yasuhiko Iwamoto; Masato Kasuga; Toshiaki Hanafusa; Masakazu Haneda; Kohjiro Ueki
Journal:  J Diabetes Investig       Date:  2010-10-19       Impact factor: 4.232

View more
  1 in total

1.  Glycated haemoglobin and fasting plasma glucose tests in the screening of outpatients for diabetes and abnormal glucose regulation in Uganda: A diagnostic accuracy study.

Authors:  Francis Xavier Kasujja; Roy William Mayega; Meena Daivadanam; Elizabeth Ekirapa Kiracho; Ronald Kusolo; Fred Nuwaha
Journal:  PLoS One       Date:  2022-08-04       Impact factor: 3.752

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.