Literature DB >> 29145092

Ionic liquid solvent bar micro-extraction of CdCln(n-2)- species for ultra-trace Cd determination in seawater.

Belén Herce-Sesa1, José A López-López2, Carlos Moreno1.   

Abstract

Water analysis of trace metals has been benefited by recent studies on sample preparation by liquid micro-extraction. However, there are still limitations for its application to seawater, such as the need of additives to preserve the sample or the availability of chemical extractants for the selective extraction from highly saline samples. In this work, a three phase solvent bar micro-extraction (3SBME) system containing the ionic liquid trioctylmethylammonium chloride (Aliquat® 336) has been used for isolation and pre-concentration of Cd from seawater samples, due to its ability for ionic exchange of CdCln(n-2)-. The system was optimized to work at the natural pH of seawater, and conditions for application to real samples were 0.18 M Aliquat® 336 dissolved in kerosene with 0.25 M dodecan-1-ol as organic solution, 1.5 M HNO3 as acceptor solution, 60 min extraction time, and 800 rpm stirring speed in the sample. Loss of organic solution into the sample during extraction was evaluated and revealed its dependence on stirring rate and extraction time. Under optimum conditions samples containing Cd 0.09-0.90 nM were pre-concentrated 65 times. GF-AAS was used for metal quantification with a limit of detection of 0.04 nM. Accuracy was successfully evaluated measuring Cd in a seawater certified reference material BCR-403.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cadmium; Hollow fiber; Ionic liquid; Seawater; Solvent bar micro-extraction; Ultra-trace analysis

Mesh:

Substances:

Year:  2017        PMID: 29145092     DOI: 10.1016/j.chemosphere.2017.11.004

Source DB:  PubMed          Journal:  Chemosphere        ISSN: 0045-6535            Impact factor:   7.086


  3 in total

1.  Novel 3-Hydroxy-2-Naphthoate-Based Task-Specific Ionic Liquids for an Efficient Extraction of Heavy Metals.

Authors:  Philip Pirkwieser; José A López-López; Wolfgang Kandioller; Bernhard K Keppler; Carlos Moreno; Franz Jirsa
Journal:  Front Chem       Date:  2018-05-23       Impact factor: 5.221

2.  An Efficient Polymer Inclusion Membrane-Based Device for Cd Monitoring in Seawater.

Authors:  Ibrahim Ait Khaldoun; Lynda Mitiche; Amar Sahmoune; Clàudia Fontàs
Journal:  Membranes (Basel)       Date:  2018-08-10

3.  Solvent Bar Micro-Extraction of Heavy Metals from Natural Water Samples Using 3-Hydroxy-2-Naphthoate-Based Ionic Liquids.

Authors:  Philip Pirkwieser; José A López-López; Wolfgang Kandioller; Bernhard K Keppler; Carlos Moreno; Franz Jirsa
Journal:  Molecules       Date:  2018-11-17       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.