| Literature DB >> 29142649 |
Afnan F Al-Fouzan1, Lamya A Al-Mejrad1, Ahmed M Albarrag2.
Abstract
PURPOSE: The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases.Entities:
Keywords: Adhesion; CAD/CAM; Candida; Complete denture; Edentulous; Roughness
Year: 2017 PMID: 29142649 PMCID: PMC5673618 DOI: 10.4047/jap.2017.9.5.402
Source DB: PubMed Journal: J Adv Prosthodont ISSN: 2005-7806 Impact factor: 1.904
Fig. 1Surface roughness of the CAD/CAM complete denture base.
Fig. 2Surface roughness of the conventional complete denture base.
Fig. 3Candida cells adhered to the conventional discs (stained with acridine orange).
Fig. 4Candida cells adhered to the CAD/CAM discs (stained with acridine orange).
Adhesion of Candida albicans isolates (CA-1 to CA-4) to the conventional and CAD/CAM discs
| Candida albicans isolates | Conventional CFU/mL | CAD/CAM CFU/mL | % Reduction in adherence (± SD) | |||
|---|---|---|---|---|---|---|
| Mean | SD | Mean | SD | |||
| CA-1 | 2.3 × 103 | 8.4 × 102 | 1.1 × 103 | 6.0 × 102 | 51.7 ± 17.1 | .0364 |
| CA-2 | 5.4 × 103 | 1.6 × 102 | 2.1 × 103 | 8.7 × 102 | 60.2 ± 17.8 | .0041 |
| CA-3 | 2.0 × 103 | 9.7 × 102 | 1.2 × 103 | 8.8 × 102 | 47.2 ± 24.8 | .0448 |
| CA-4 | 2.4 × 103 | 1.1 × 103 | 1.5 × 103 | 7.2 × 102 | 35.7 ± 19.1 | .0648 |
Comparison of the surface roughness of the complete denture surface (CAD/CAM vs. conventional)
| Complete denture surface | Mean (µm) | SD (µm) | |
|---|---|---|---|
| Sa | |||
| CAD/CAM | 0.037 | 0.001 | |
| Conventional | 0.073 | 0.015 | .020 |