Literature DB >> 29142649

Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures.

Afnan F Al-Fouzan1, Lamya A Al-Mejrad1, Ahmed M Albarrag2.   

Abstract

PURPOSE: The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases.
MATERIALS AND METHODS: Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy.
RESULTS: There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure (P<.05).
CONCLUSION: The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.

Entities:  

Keywords:  Adhesion; CAD/CAM; Candida; Complete denture; Edentulous; Roughness

Year:  2017        PMID: 29142649      PMCID: PMC5673618          DOI: 10.4047/jap.2017.9.5.402

Source DB:  PubMed          Journal:  J Adv Prosthodont        ISSN: 2005-7806            Impact factor:   1.904


INTRODUCTION

Edentulism is a “debilitating and irreversible condition and is described as the final marker of disease burden for oral health.”12 Among older adults, edentulism is considered one of the most prevalent condition worldwide3 although the percentage of tooth loss has decreased in recent years.4 In the U.S., the prevalence of edentulism is 15% in patients between the ages of 65 and 74 years old and 22% in patients older than 75 years according to the National Health and Nutrition Examination Survey.3 Emami et al.2 reported that the majority of edentulous patients wear one or two complete dentures. The use of removable prostheses has increased due to the increasing number of older patients, who are the primary wearers of dentures, in the general population.4 Being edentulous influences oral health and general well-being.2 The effects on oral health include impaired masticatory efficiency and denture-related oral lesions, such as angular cheilitis, traumatic ulcers and denture stomatitis (DS).56 DS is an inflammation of the mucosa underlying a removable prosthesis.7 Shulman et al.8 conducted a study in the U.S. and found that the prevalence of DS among denture wearers was 28%.8 Another epidemiological study reported that the prevalence of DS was highest among elderly and female denture wearers.9 In addition, that study stated that the prevalence of DS ranged from 15% to over 70%.9 Sadig10 conducted a study in 2010 that reported the incidence of DS to be approximately 62%. Many factors might lead to the development of DS.11 Some of these are related to systemic and immune diseases and impaired salivary flow, and others are related to the dentures themselves, such as poor denture hygiene, denture-induced trauma, roughness and the presence of pores in the acrylic surface.11 Among these factors, Candida colonization is well established as a predisposing factor for the denture wearers experiencing development of denture stomatitis.1213 All the previously mentioned factors contribute to Candida colonization on denture and mucosal surfaces.10 Candida is not harmful by itself, and studies have demonstrated that it is part of the normal flora.11 There are 20 species of Candida among the 300 to 400 species of microorganisms in the oral cavity.14 The presence of Candida ranges from 20% to 50% in healthy dentate individuals.1516 Becoming edentulous and wearing dentures both cause changes in the oral microbial flora, which lead to an increase in Candida colonization as high as 60% to 100%.1117 Candida has the ability to grow on targeted surfaces in several ways.18 One of the ways is the formation of biofilms, which are significant causes of infection.18 The adhesion of Candida to the oral mucosa is an important factor in the resistance to host clearance mechanisms in the oral cavity. Among other Candida species, Candida albicans is the most prevalent isolated species in DS, followed by Candida glabrata.9111219 Other Candida species, such as Candida krusei, Candida Kefyr, Candida parapsilosis, and Candida tropicalis, occur at lower prevalences.91112 In addition to adhesion to the oral mucosa, the adhesion of Candida to acrylic is considered to be a critical factor in the development of DS.2021 This adhesion occurs through the formation of biofilms on the denture surface that act as protective reservoirs that prevent Candida from being washed away by saliva or dislodgment forces.19 Many studies have proven that both Candida albicans and Candida glabrata form these biofilms on denture surfaces.11222324 Several studies have linked the surface characteristics of denture acrylics to the amount of Candida biofilm adhesion.2526 Ramage et al.21 reported that imperfections on the denture surface contribute to an increase in the adhesion of Candida, which becomes imbedded within these imperfections. Other studies have also confirmed that surface roughness and surface crevices facilitate Candida colonization on denture surfaces.27 In a review, Bidra et al.28 reported that decreasing the porosity decreases Candida adhesion. Conventional heat-cured poly(methyl methacrylate) (PMMA) is the most popular material for dentures.29 It has been proven that this curing method increases the number of pores in the denture surface.29 In 1994, the first report in English to discuss the use of computer-aided technology (CAD/CAM) in the fabrication of complete denture with rapid prototyping technology was published.30 Numerous CAD/CAM denture systems appear in the market, the dentures are milled from pre-polymerized pucks of resin.3132 CAD/CAM-fabricated complete dentures have several advantages over conventionally fabricated complete dentures.28 One of these is a decrease in porosity because with CAD/CAM, the denture base is formed from a prepolymerized block of acrylic resin.28 This decrease in porosity might decrease the adhesion of Candida to the dentures.28 Also CAD/CAM fabricated dentures release a small amount of monomer, which may affect microbial adhesion and trigger a mucosal allergy reaction, but this effect is not as statistically significantly as the conventional dentures.32 Usually the internal surface of complete denture is not highly polished which may affect the roughness threshold of microbial adhesion.33 Therefore, the aim of the present study was to compare the adhesion of Candida on the surfaces of CAD/CAM and conventionally fabricated complete denture bases. The null hypothesis was that there would be no difference in Candida adhesion between the CAD/CAM and conventionally fabricated complete denture bases.

MATERIALS AND METHODS

Twenty discs of Pink acrylic resin denture bases were fabricated with CAD/CAM and conventional procedures. The specimens were divided into two groups: discs that were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent, Schaan, Liechtenstein) and discs that were fabricated using a conventional flasking and pressure-pack technique. Ten discs were fabricated from PMMA acrylic resin denture base material (major.base20 heat-processed PMMA, Moncalieri (TO), Italy) using a conventional flasking and pressure-pack technique. A stainless steel disc-shaped mold (3 × 10 mm) was used to make the discs according to the manufacturer's instructions. The discs were cleaned with a steam jet (Wasi-Steam Classic, Wassermann Dental-Maschinen, Hamburg, Germany) after the deflasking procedure. The excess flash was removed using carbide cutters (Black Hawk Cutter, Horeco, Hopf, Ringleb & Co. GmbH & CIE, Berlin, Germany). The surface was finished with waterproof paper. Next, polishing was performed with a polishing compact unit (Derotor, London, England) consisting of a polishing lathe, a 45-mm polishing brush, and a pleated buff nettle cloth (Renfert GmbH, Industrie-gebiet, Hilzingen, Germany) with pumice (Pumice CL 60, Coarse Grade, Whip Mix Corporation, Louisville, KY, USA). Finally, the discs were cleaned with water and soap using a regular toothbrush followed by a steam jet. Ten discs of 10 × 3 mm were designed using Zenotec CAD software (Wieland Digital Denture Ivoclar Vivadent, Schaan, Liechtenstein). PMMA blocks were used (opera system, Principauté de Monaco, French). Milling was performed using Zenotec select ion (Wieland Digital Denture Ivoclar Vivadent, Schaan, Liechtenstein). These discs were finished and polished following the same procedures used for the discs made with the conventional method. For both CAD/CAM and conventional denture materials, 30 readings were taken from randomly selected spots on the surface of each disc and subjected to surface roughness analysis. The measurements were made using a non-contact optical three-dimensional profilometer (Contour GT-I, Bruker) (Fig. 1, Fig. 2). Roughness is expressed as the surface area roughness (Sa, µm).
Fig. 1

Surface roughness of the CAD/CAM complete denture base.

Fig. 2

Surface roughness of the conventional complete denture base.

Candida isolates were subcultured on Sabouraud dextrose agar (SDA) (Oxoid, Hampshire, UK) for 24 hours at 37℃. The isolates were identified to the species level using the germ tube test and API20C-AUX methods. For the preparation of the yeast suspensions, the cells were inoculated in Sabouraud dextrose broth (SDB) (Oxoid, UK) and incubated for 18 hours at 37℃ with shaking at 150 rpm. The yeast cells were harvested by centrifugation at 3000 g for 10 min and washed twice with phosphate-buffered saline (PBS; pH 7.0). The cell density was adjusted to 1 × 107 cells/mL in SDB. Biofilm formation by the Candia albicans clinical isolates was investigated with the microtiter plate method, as described previously.34 From the biofilm screening assays, four Candida albicans isolates (CA-1, CA-2, CA-3, and CA-4) were selected for the adherence assay based on their ability to form biofilms. Biofilm-producing Candida albicans isolates were selected for the adherence assay. The discs were disinfected using 70% alcohol and washed with sterile distilled water before use in the adherence assay. For the adherence assay, yeast cells from a fresh culture were added to the SDB medium to a final concentration of 1 × 107 cells/mL. The discs of dental materials were placed in a 24-well tissue culture plate (Corning, St. Louis, MO, USA), and 1 mL of the yeast cell suspension was added. The plate was incubated for 90 min at 37℃ with shaking at 75 rpm. After incubation, the discs were transferred to new wells and washed three times with PBS to remove the non-adherent cells. The adherent Candida cells were dislodged from the surfaces of the dentures in 2 mL of PBS by scraping and vortexing for 5 minutes. The cell suspension was then gently sonicated for 3 minutes and plated on SDA. The colony-forming unit (CFU) counts were determined after 24 hours of incubation at 37℃. The determinations of the CFU counts were repeated on three different occasions separately for the four Candida albicans isolates with fresh cultures and adherence to the two different denture materials. The number of adherent cells is expressed as CFU/mL. Candida was applied to the two types of discs (20 discs) and allowed to adhere as described above. After washing, the discs were stained with acridine orange (AO) (Sigma Aldrich, St. Louis, MO, USA) for 5 minutes, and the excess stain was gently rinsed off with PBS. The discs were examined under a fluorescent microscope (SMZ25, Nikon, Tokyo, Japan). Images were captured and analyzed using NIS-Elements imaging and analysis software (Nikon, Tokyo, Japan) (Fig. 3, Fig. 4).
Fig. 3

Candida cells adhered to the conventional discs (stained with acridine orange).

Fig. 4

Candida cells adhered to the CAD/CAM discs (stained with acridine orange).

Descriptive statistics were used to describe the Candida albicans isolate adhesion values for the conventional and CAD/CAM complete dentures. Student's t test was used to compare the adhesion of the Candida albicans isolates and the surface roughnesses between the CAD/CAM and conventional complete denture bases. A P value of < 0.5 was considered statistically significant.

RESULTS

This study assessed the adherence of Candida albicans to the surface of denture bases materials manufactured in two different ways. Table 1 presents the mean Candida albicans isolate adhesion values and their standard deviations for the conventional and CAD/CAM complete dentures. The conventional complete denture surface exhibited a higher adherence of Candida albicans isolates than did the CAD/CAM surface. The percentage of reduction in the adhesion of Candida albicans (CA-1, CA-2 and CA-3) on the CAD/CAM complete dentures was significantly lower than on the conventional dentures (P < .05).
Table 1

Adhesion of Candida albicans isolates (CA-1 to CA-4) to the conventional and CAD/CAM discs

Candida albicans isolatesConventional CFU/mLCAD/CAM CFU/mL% Reduction in adherence (± SD)P value
MeanSDMeanSD
CA-12.3 × 1038.4 × 1021.1 × 1036.0 × 10251.7 ± 17.1.0364
CA-25.4 × 1031.6 × 1022.1 × 1038.7 × 10260.2 ± 17.8.0041
CA-32.0 × 1039.7 × 1021.2 × 1038.8 × 10247.2 ± 24.8.0448
CA-42.4 × 1031.1 × 1031.5 × 1037.2 × 10235.7 ± 19.1.0648
Table 2 presents the surface roughness of the complete denture surface. The conventional complete denture surface exhibited a surface roughness that was significantly greater than that of the CAD/CAM dentures.
Table 2

Comparison of the surface roughness of the complete denture surface (CAD/CAM vs. conventional)

Complete denture surfaceMean (µm)SD (µm)P value
Sa
CAD/CAM0.0370.001
Conventional0.0730.015.020
The adherence ability was also assessed with acridin orange staining and observation under a fluorescent microscope. The number of yeast cells that adhered to the CAD/CAM discs was lower than the number that adhered to the conventional discs. This microscopic observation is in agreement with and confirms the CFU count. Four different Candida albicans isolates were used in this study to ensure that the outcome of the study was not influenced by biological differences in the Candida strains.

DISCUSSION

The null hypothesis of this study was rejected because there was a difference in Candida adhesion between the CAD/CAM and the conventionally fabricated complete denture bases. In the present study, the adhesion of Candida albicans to the CAD/CAM and conventionally fabricated complete denture base surfaces was evaluated. The CFU count, which reflects cell adherence to the denture base, was used to assess the difference in adherence. Interestingly, Candida albicans exhibited differing adherence ability to the two different denture bases. Candida albicans adhered to the CAD/CAM base with a lower affinity than it did to the conventional denture base, which had greater surface roughness than CAD/CAM base. The mechanism by which Candida species cause denture stomatitis can be summarized as follows. Candida can form biofilms on mucosal and denture surfaces that promote plaque deposition on the denture surface.9 This deposition causes the mucosa to be continuously exposed to the microorganisms in the biofilm, which eventually causes DS.9 These biofilms are important contributors to the development of DS.35 Candida albicans is the most frequently isolated species in such biofilms.9111219 The capability of Candida albicans to adhere to and form biofilms on PMMA varies.36 The presence of a denture in the oral cavity facilitates the adherence of Candida albicans and causes infection.37 The reasons for the popularity of PMMA include its ease of handling, low cost, and esthetics.38 However, it has many disadvantages, including its dimensional instability, residual monomer content, weak strength, water absorption, color instability, and porosity. Porosity is considered to be a shortcoming when it exceeds 11% because at this point, the mechanical properties and esthetics are compromised, and the material becomes a reservoir for microorganisms.29 In 1968, the Academy of Denture Prosthetics stated that dentures should be free of pores to ensure adequate cleaning and resistance to stains and the adherence of microorganisms.38 According to the American Dental Association's specifications for the porosity of denture base polymers, “there shall be no bubbles or voids when viewed without magnification”.39 Conventional heat-cured PMMA is the most common curing technique.29 Porosity in heat-cured PMMA denture bases is an unfavorable result. Porosity can be caused by : air trapped during mixing, monomer contraction during polymerization, monomer vaporization associated with the exothermic reaction and the presence of residual monomer, insufficient mixing of monomer and polymer, a processing temperature higher than 74℃, the way the mold is packed, and inadequate compression on the flask.40414243 The surface characteristics of the denture might contribute to an increase in Candida colonization due to hydrophobicity and roughness.2526 Roughness is an important factor; the rougher the surface, the greater the Candida colonization will be.25 There are several methods and devices available to measure the surface roughness, including visual assessments, scanning electron microscopy, profilometry, laser specular reflectance, and atomic force microscopy.44 Profilometry is a common device for measuring surface roughness.45 Profilometry can be performed with either contact or non-contact methods.46 In this study, a non-contact optical three-dimensional profilometer was used. The non-contact method uses a laser or light beam to obtain a surface profile.47 Kukiattrakoon et al.47 claimed that one of the disadvantages of the contact method is that it can damage the surface by producing scratches. However, one study reported that not all irregularities in specimens can be penetrated by the sensor needle of a mechanical profilometer.48 In the present study, an optical laser profilometer that provided a three-dimensional profile was used. According to Joniot et al.,49 this method provides a non-contact, non-destructive, and rapid quantitative measurement of surface roughness. As mentioned earlier, increased porosity has been proven to increase microorganism colonization.4850 Over the past several years, many attempts have been made to improve both the material properties and the curing and processing techniques.29 The advantage of the CAD/CAM method over the conventional method is that a prepolymerized block of acrylic resin is used to mill the denture base.28 The elimination of mixing used in the conventional procedures will decrease the porosity, which will ultimately decrease Candida adhesion. This study is considered one of the first studies that used microbiological essay comparing CAD/CAM and conventional procedure to fabricate dentures.

CONCLUSION

Alterations of denture surface characteristics, such as porosity and surface roughness, contribute to a decrease in Candida adhesion, which ultimately decreases the risk of denture stomatitis. The surface characteristics of complete dentures fabricated with the CAD/CAM procedure exhibited promising potential for reducing the adherence of Candida to the denture base surface. Moreover, the adhesion of Candida albicans to the surfaces is significantly affected by the interactions with other microorganisms in the oral cavity. Therefore, further research is needed to fully determine the difference in adhesion to the surface of these denture base materials in complex Candida and bacterial models beside in vivo studies. Also different CAD/CAM systems with different surface roughness can be tested.
  47 in total

Review 1.  Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives.

Authors:  Avinash S Bidra; Thomas D Taylor; John R Agar
Journal:  J Prosthet Dent       Date:  2013-06       Impact factor: 3.426

2.  Will there be a need for complete dentures in the United States in 2020?

Authors:  Chester W Douglass; Annie Shih; Larry Ostry
Journal:  J Prosthet Dent       Date:  2002-01       Impact factor: 3.426

Review 3.  Factors involved in microbial colonization of oral prostheses.

Authors:  J A von Fraunhofer; Z G Loewy
Journal:  Gen Dent       Date:  2009 Mar-Apr

4.  The denture hygiene, denture stomatitis and role of dental hygienist.

Authors:  W Sadig
Journal:  Int J Dent Hyg       Date:  2010-08       Impact factor: 2.477

5.  Biofilm formation by the fungal pathogen Candida albicans: development, architecture, and drug resistance.

Authors:  J Chandra; D M Kuhn; P K Mukherjee; L L Hoyer; T McCormick; M A Ghannoum
Journal:  J Bacteriol       Date:  2001-09       Impact factor: 3.490

6.  Candida albicans and denture stomatitis: evaluation of its presence in the lesion, prosthesis, and blood.

Authors:  Carine Ervolino de Oliveira; Thaís Helena Gasparoto; Thiago José Dionísio; Vinicius Carvalho Porto; Narciso Almeida Vieira; Carlos Ferreira Santos; Vanessa Soares Lara
Journal:  Int J Prosthodont       Date:  2010 Mar-Apr       Impact factor: 1.681

7.  Investigating biofilm production, coagulase and hemolytic activity in Candida species isolated from denture stomatitis patients.

Authors:  Nimet Yigit; Esin Aktas; Saadettin Dagistan; Ahmet Ayyildiz
Journal:  Eurasian J Med       Date:  2011-04

Review 8.  Oral mycoses in HIV infection.

Authors:  L P Samaranayake
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1992-02

9.  Participation of yeast cell surface hydrophobicity in adherence of Candida albicans to human epithelial cells.

Authors:  K C Hazen
Journal:  Infect Immun       Date:  1989-07       Impact factor: 3.441

10.  Effect of acidic agents on surface roughness of dental ceramics.

Authors:  Boonlert Kukiattrakoon; Chanothai Hengtrakool; Ureporn Kedjarune-Leggat
Journal:  Dent Res J (Isfahan)       Date:  2011
View more
  9 in total

1.  Effect of finishing/polishing techniques and aging on topography, C. albicans adherence, and flexural strength of ultra-translucent zirconia: an in situ study.

Authors:  Isabelle Helena Gurgel de Carvalho; Nathalia Ramos da Silva; Taciana Emília Leite Vila-Nova; Leopoldina de Fatima Dantas de Almeida; Aretha Heitor Veríssimo; Renata Marques de Melo; Yu Zhang; Rodrigo Othávio de Assunção E Souza
Journal:  Clin Oral Investig       Date:  2021-08-27       Impact factor: 3.573

2.  In vitro study of surface properties and microbial adhesion of various dental polymers fabricated by different manufacturing techniques after thermocycling.

Authors:  Xia Wei; Linjuan Gao; Kun Wu; Yu Pan; Lei Jiang; Honglei Lin; Yinghui Wang; Hui Cheng
Journal:  Clin Oral Investig       Date:  2022-08-17       Impact factor: 3.606

Review 3.  Assessment of Conventionally and Digitally Fabricated Complete Dentures: A Comprehensive Review.

Authors:  Manal Q Mubaraki; Mohammed M Al Moaleem; Abdulrahman H Alzahrani; Mansoor Shariff; Saeed M Alqahtani; Amit Porwal; Fuad A Al-Sanabani; Shilpa Bhandi; João Paulo Mendes Tribst; Artak Heboyan; Shankargouda Patil
Journal:  Materials (Basel)       Date:  2022-05-28       Impact factor: 3.748

4.  Fibrin Biopolymer Incorporated with Antimicrobial Agents: A Proposal for Coating Denture Bases.

Authors:  Helena Sandrini Venante; Ana Paula Chappuis-Chocano; Oscar Oswaldo Marcillo-Toala; Rafaela Alves da Silva; Rodrigo Moreira Bringel da Costa; Mariana Domingues Pordeus; Benedito Barraviera; Rui Seabra Ferreira Junior; Vanessa Soares Lara; Karin Hermana Neppelenbroek; Heitor Marques Honório; Vinicius Carvalho Porto
Journal:  Materials (Basel)       Date:  2021-03-26       Impact factor: 3.623

5.  Surface Characteristics of Milled and 3D Printed Denture Base Materials Following Polishing and Coating: An In-Vitro Study.

Authors:  Pablo Kraemer Fernandez; Alexey Unkovskiy; Viola Benkendorff; Andrea Klink; Sebastian Spintzyk
Journal:  Materials (Basel)       Date:  2020-07-24       Impact factor: 3.623

6.  Microbial Adhesion to Dental Polymers for Conventional, Computer-Aided Subtractive and Additive Manufacturing: A Comparative In Vitro Study.

Authors:  Sergey Arutyunov; Levon Kirakosyan; Lubov Dubova; Yaser Kharakh; Nikolay Malginov; Gadzhi Akhmedov; Viktor Tsarev
Journal:  J Funct Biomater       Date:  2022-04-11

7.  Evaluation of biofilm formation on acrylic resins used to fabricate dental temporary restorations with the use of 3D printing technology.

Authors:  Justyna Mazurek-Popczyk; Adam Nowicki; Katarzyna Arkusz; Łukasz Pałka; Anna Zimoch-Korzycka; Katarzyna Baldy-Chudzik
Journal:  BMC Oral Health       Date:  2022-10-13       Impact factor: 3.747

8.  Influence of the Manufacturing Method on the Adhesion of Candida albicans and Streptococcus mutans to Oral Splint Resins.

Authors:  Andrea Schubert; Ralf Bürgers; Franziska Baum; Oliver Kurbad; Torsten Wassmann
Journal:  Polymers (Basel)       Date:  2021-05-11       Impact factor: 4.329

9.  Silver Nanoparticles Addition in Poly(Methyl Methacrylate) Dental Matrix: Topographic and Antimycotic Studies.

Authors:  Valeria De Matteis; Mariafrancesca Cascione; Chiara Cristina Toma; Giovanni Albanese; Maria Luisa De Giorgi; Massimo Corsalini; Rosaria Rinaldi
Journal:  Int J Mol Sci       Date:  2019-09-21       Impact factor: 5.923

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.