Literature DB >> 29137728

A computational model for false lumen thrombosis in type B aortic dissection following thoracic endovascular repair.

Claudia Menichini1, Zhuo Cheng1, Richard G J Gibbs2, Xiao Yun Xu3.   

Abstract

Thoracic endovascular repair (TEVAR) has recently been established as the preferred treatment option for complicated type B dissection. This procedure involves covering the primary entry tear to stimulate aortic remodelling and promote false lumen thrombosis thereby restoring true lumen flow. However, complications associated with incomplete false lumen thrombosis, such as aortic dilatation and stent graft induced new entry tears, can arise after TEVAR. This study presents the application and validation of a recently developed mathematical model for patient-specific prediction of thrombus formation and growth under physiologically realistic flow conditions. The model predicts thrombosis through the evaluation of shear rates, fluid residence time and platelet distribution, based on convection-diffusion-reaction transport equations. The model was applied to 3 type B aortic dissection patients: two TEVAR cases showing complete and incomplete false lumen thrombosis respectively, and one medically treated dissection with no signs of thrombosis. Predicted thrombus growth over time was validated against follow-up CT scans, showing good agreement with in vivo data in all cases with a maximum difference between predicted and measured false lumen reduction below 8%. Our results demonstrate that TEVAR-induced thrombus formation in type B aortic dissection can be predicted based on patient-specific anatomy and physiologically realistic boundary conditions. Our model can be used to identify anatomical or stent graft related factors that are associated with incomplete false lumen thrombosis following TEVAR, which may help clinicians develop personalised treatment plans for dissection patients in the future.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Aortic dissection; CFD; False lumen; Hemodynamics; TEVAR; Thrombosis

Mesh:

Year:  2017        PMID: 29137728     DOI: 10.1016/j.jbiomech.2017.10.029

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  8 in total

1.  A Hemodynamic Analysis of the Thrombosis Within Occluded Coronary Arterial Fistulas With Terminal Aneurysms Using a Blood Stasis Model.

Authors:  Xudong Jiang; Haoyao Cao; Zijian Zhang; Tinghui Zheng; Xiaoqiang Li; Peng Wu
Journal:  Front Physiol       Date:  2022-05-23       Impact factor: 4.755

2.  The Necessity to Seal the Re-Entry Tears of Aortic Dissection After TEVAR: A Hemodynamic Indicator.

Authors:  Zhenfeng Li; Huanming Xu; Chlöe Harriet Armour; Yuze Guo; Jiang Xiong; Xiaoyun Xu; Duanduan Chen
Journal:  Front Bioeng Biotechnol       Date:  2022-03-31

3.  The influence of inlet velocity profile on predicted flow in type B aortic dissection.

Authors:  Chlöe Harriet Armour; Baolei Guo; Selene Pirola; Simone Saitta; Yifan Liu; Zhihui Dong; Xiao Yun Xu
Journal:  Biomech Model Mechanobiol       Date:  2020-10-17

4.  An integrated fluid-structure interaction and thrombosis model for type B aortic dissection.

Authors:  Mei Yan Chong; Boram Gu; Chlöe Harriet Armour; Socrates Dokos; Zhi Chao Ong; Xiao Yun Xu; Einly Lim
Journal:  Biomech Model Mechanobiol       Date:  2022-01-25

5.  Computational Prediction of Thrombosis in Food and Drug Administration's Benchmark Nozzle.

Authors:  Yonghui Qiao; Kun Luo; Jianren Fan
Journal:  Front Physiol       Date:  2022-04-25       Impact factor: 4.755

6.  Influence of MRI-based boundary conditions on type B aortic dissection simulations in false lumen with or without abdominal aorta involvement.

Authors:  Dongting Liu; Xuan Wang; Dongliang Zhao; Zhonghua Sun; Jumatay Biekan; Zhaoying Wen; Lei Xu; Jiayi Liu
Journal:  Front Physiol       Date:  2022-09-07       Impact factor: 4.755

7.  Retrospective analysis of factors associated with aortic remodeling in patients with Stanford type B aortic dissection after thoracic endovascular aortic repair.

Authors:  Biao Yu; Tangzhiming Li; Huadong Liu
Journal:  J Cardiothorac Surg       Date:  2021-07-07       Impact factor: 1.637

8.  The effect of beta-blockers on hemodynamic parameters in patient-specific blood flow simulations of type-B aortic dissection: a virtual study.

Authors:  Mohammad Amin Abazari; Deniz Rafieianzab; M Soltani; Mona Alimohammadi
Journal:  Sci Rep       Date:  2021-08-06       Impact factor: 4.379

  8 in total