Literature DB >> 29136912

A new procedure for high precision isotope ratio determinations of U, Cu and Zn at nanogram levels in cultured human cells: What are the limiting factors?

Eduardo Paredes1, Emilie Avazeri2, Véronique Malard3, Claude Vidaud2, Richard Ortega4, Anthony Nonell1, Hélène Isnard1, Frédéric Chartier5, Carole Bresson6.   

Abstract

The monitoring of isotopic fractionations in in vitro cultured human cell samples is a very promising and under-exploited tool to help identify the metabolic processes leading to disease-induced isotopic fractionations or decipher metabolic pathways of toxic metals in these samples. One of the limitations is that the analytes are often present at small amounts, ranging from tens to hundreds of ng, thus making challenging low-uncertainty isotope ratio determinations. Here we present a new procedure for U, Cu and Zn purification and isotope ratio determinations in cultured human neuron-like cells exposed to natural U. A thorough study of the influence of the limiting factors impacting the uncertainty of δ238U, δ66Zn and δ65Cu is also carried out. These factors include the signal intensity, which determines the within-day measurement reproducibility, the procedural blank correction and the matrix effects, which determine the accuracy of the mass bias correction models. Given the small Cu and U amounts in the cell samples, 15-30 and 20ng respectively, a highly efficient sample introduction system was employed in order to improve the analyte transport to the plasma and, hence, the signal intensity. With this device, the procedural blanks became the main uncertainty source of δ238U and δ65Cu values, accounting over 65% of the overall uncertainty. The matrix effects gave rise to inaccuracies in the mass bias correction models for samples finally dissolved in the minimal volumes required for the analysis, 100-150µL, leading to biases for U and Cu. We will show how these biases can be cancelled out by dissolving the samples in volumes of at least 300µL for Cu and 450µL for U. Using our procedure, expanded uncertainties (k = 2) of around 0.35‰ for δ238U and 0.15‰ for δ66Zn and δ65Cu could be obtained. The analytical approach presented in this work is also applicable to other biological microsamples and can be extended to other elements and applications.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biological samples uranium; Cooper zinc; Isotopic analysis; Method development

Mesh:

Substances:

Year:  2017        PMID: 29136912     DOI: 10.1016/j.talanta.2017.10.046

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  1 in total

1.  Impact of uranium uptake on isotopic fractionation and endogenous element homeostasis in human neuron-like cells.

Authors:  Eduardo Paredes; Emilie Avazeri; Véronique Malard; Claude Vidaud; Pascal E Reiller; Richard Ortega; Anthony Nonell; Hélène Isnard; Frédéric Chartier; Carole Bresson
Journal:  Sci Rep       Date:  2018-11-21       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.