Literature DB >> 29136849

Simultaneous determination of three estrogens in human saliva without derivatization or liquid-liquid extraction for routine testing via miniaturized solid phase extraction with LC-MS/MS detection.

Xiaoguang Sunny Li1, Shu Li2, Gottfried Kellermann2.   

Abstract

Accurate quantitation of estrogens (i.e, estrone (E1), estradiol (E2) and estriol (E3)) is valuable for clinical assessment of human health and disease. Alterations in estrogen levels have been implicated in numerous pathological conditions. However, inadequacies in sensitivity and specificity, cumbersome sample preparation and invasive specimen collection hamper the usability of available methods for clinical applications. Herein, a simple, rapid, highly sensitive and specific LC-MS/MS method was developed and validated for the simultaneous determination of three estrogens in human saliva providing a non-invasive alternative to conventional blood samples. For the first time, a 96-well hydrophilic-lipophilic-balanced (HLB) microplate was employed for clean-up and enrichment of estrogens in a single extraction without the requirements of derivatization, evaporation, liquid-liquid extraction and online extraction. A rapid LC chromatographic separation with a turnaround time of 5.0min was achieved on a BEH C18 XP column. The use of 0.1mM ammonium fluoride (NH4F) as LC additive, and integration of summated and scheduled multiple reaction monitoring (MRM) transitions substantially improved the sensitivity to 1pg/mL, allowing the accurate quantitation of trace levels of three estrogens in one run. The assay was fully validated with good performance for extraction efficiency (67.0-85.6%), matrix effect (89.6-100.2%), linearity (from 1.0pg/mL up to 1000pg/mL), accuracy (98.9-112.4%) and precision (≤7.4%). Additionally, the assay was unaffected by 34 structurally-similar, potentially interfering substances tested at high clinical concentrations. The applicability of the assay was demonstrated by assessing the reference intervals of authentic saliva samples from healthy adult males, pre- and post-menopausal females. The easy sample preparation, fast LC and multi-analyte MS/MS detection utilizing noninvasive saliva as a specimen delivers a simple, practical, sensitive and accurate tool suitable for the high throughput measurement of E1, E2 and E3 in clinical laboratories.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Estrogen; LC-MS/MS; Miniaturized solid phase extraction (SPE); Saliva; Scheduled multiple reaction monitoring (MRM) summation; Steroid hormone

Mesh:

Substances:

Year:  2017        PMID: 29136849     DOI: 10.1016/j.talanta.2017.09.062

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Novel deep eutectic solvent-based liquid phase microextraction for the extraction of estrogenic compounds from environmental samples.

Authors:  Nazir Fattahi; Mojtaba Shamsipur; Ziba Nematifar; Nasrin Babajani; Masoud Moradi; Shahin Soltani; Shahram Akbari
Journal:  RSC Adv       Date:  2022-05-13       Impact factor: 4.036

2.  Metabolic Alteration Analysis of Steroid Hormones in Niemann-Pick Disease Type C Model Cell Using Liquid Chromatography/Tandem Mass Spectrometry.

Authors:  Ai Abe; Masamitsu Maekawa; Toshihiro Sato; Yu Sato; Masaki Kumondai; Hayato Takahashi; Masafumi Kikuchi; Katsumi Higaki; Jiro Ogura; Nariyasu Mano
Journal:  Int J Mol Sci       Date:  2022-04-18       Impact factor: 6.208

Review 3.  Current strategies for quantification of estrogens in clinical research.

Authors:  Nina Denver; Shazia Khan; Natalie Z M Homer; Margaret R MacLean; Ruth Andrew
Journal:  J Steroid Biochem Mol Biol       Date:  2019-05-18       Impact factor: 4.292

Review 4.  Analytical Methods for the Determination of Neuroactive Steroids.

Authors:  Michal Kaleta; Jana Oklestkova; Ondřej Novák; Miroslav Strnad
Journal:  Biomolecules       Date:  2021-04-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.