| Literature DB >> 29134356 |
Trond Engjom1,2, Erling Tjora3,4, Gaute Wathle5, Friedemann Erchinger6,7, Birger N Lærum4, Odd H Gilja6,8, Ingfrid Salvesen Haldorsen6,5, Georg Dimcevski6,9.
Abstract
OBJECTIVES: Secretin-stimulated magnetic resonance imaging (s-MRI) is the best validated radiological modality assessing pancreatic secretion. The purpose of this study was to compare volume output measures from secretin-stimulated transabdominal ultrasonography (s-US) to s-MRI for the diagnosis of exocrine pancreatic failure in cystic fibrosis (CF).Entities:
Keywords: Cystic fibrosis; Exocrine pancreatic insufficiency; Magnetic resonance imaging; Secretin; Ultrasonography
Mesh:
Substances:
Year: 2017 PMID: 29134356 PMCID: PMC5834563 DOI: 10.1007/s00330-017-5115-2
Source DB: PubMed Journal: Eur Radiol ISSN: 0938-7994 Impact factor: 5.315
Fig. 1US image from the descending part of the duodenum illustrating fluid filling before (A, C) and 15 minutes after secretin stimulation (B, D). The upper panels demonstrate a pancreas-insufficient patient, whereas the lower panels demonstrate a pancreas-sufficient CF patient. Markings illustrate the duodenal diameter and duodenal area tracing. Also note the hyperechoic and atrophic appearance of the affected pancreas. d, duodenum; g, gallbladder; l, liver; p, pancreas
Fig. 2T2-weighted MRI images before (A, C) and 13 minutes after secretin stimulation (B, D) with hyper-intense fluid signal segmented in red within defined region of interest comprising the duodenum and jejunum (boundaries marked with red). The upper panels demonstrate a pancreas-insufficient patient, whereas the lower panels demonstrate a pancreas-sufficient CF patient. d: duodenum, v: ventricle, j: jejunum
Table presenting core demographic data and data for pancreatic exocrine function
| CFI | CFS | HC | |
|---|---|---|---|
| Number (males) | 10 (5) | 11 (5) | 13 (5) |
| Age years (SD) | 29.3 (13,4) | 27.3 (12.5) | 40.7 (13.0)* |
| BMI (SD) | 21.6 (2.1) | 24.3 (4.1) | 23.7 (2.7) |
| Sweat chloride mmol/l (SD) | 111.7 (18.7)* | 69.6 (7.6) | N/A |
| Duodenal bicarbonate mEq/L (SD) | 10.4 (9.8)# | 97.8 (32.1) | 116.9 (12.6) |
| Faecal elastase μg/g (SD) | 1.2 (1.8)# | 541.4 (156.3) | 569.0 (111.0) |
| Volume EST mL | 1.7 (1.5)# | 7.6 (3.6) † | 11.5 (3.7) |
CFI: pancreas-insufficient cystic fibrosis, CFS: pancreas-sufficient cystic fibrosis, HC: healthy controls, SD: standard deviation. Volume EST: Aspirated volume for endoscopic secretin test. *p < 0.05 compared to CFS, # p < 0.05 compared to CFS and HC, †p = 0.021 compared to HC.
Table presenting secretory estimates for US and MRI
| CFI | CFS | HC | |
|---|---|---|---|
| MRI intestinal volume mL (SD) | 10.7 (7.8)* | 79.7 (26.0) | 87.0 (23.9) |
| MRI time-series AUC (SD) | 102.8 (78.7)* | 660.5 (263.3) | 716.8 (228.4) |
| US fluid-filled duodenal area cm2 (SD) | 1.4 (0.6)* | 4.9 (2.2)# | 6.6 (1.5) |
| US time-series AUC (SD) | 13.5 (6.4)* | 49.3 (22.6) | 64.9 (19.7) |
CFI: pancreas-insufficient cystic fibrosis, CFS: pancreas-sufficient cystic fibrosis, HC: healthy controls, SD: standard deviation, MRI: magnetic resonance imaging, US: ultrasonography, AUC: area under the curve. *p < 0.001 compared to CFS and HC, #p = 0.037 compared to HC.
Fig. 3US and MRI estimates of intestinal fluid filling at different time points after secretin stimulation. Error bars represent standard error of the mean. A: Changes in fluid-filled areas in sections of the descending duodenum estimated by US. B: Changes in fluid volume of the duodenum and proximal jejunum estimated by MRI. CFI: pancreas-insufficient cystic fibrosis, CFS: pancreas-sufficient cystic fibrosis, HC: healthy control
Fig. 4Panel A displays the correlation between peak values of intestinal fluid volumes estimated by MRI and peak values of fluid filled areas in sections of the descending duodenum estimated by US. There was a significant positive correlation (r2 = 0.62, p < 0.001). Panel B displays receiver operating characteristic curves peak intestinal fluid volumes estimated by MRI and peak fluid-filled areas in the descending duodenum, estimated by US. The difference between the AUROCs did not reach significance. MRI: magnetic resonance imaging, US: ultrasonography, CFI: pancreas-insufficient cystic fibrosis, CFS: pancreas-sufficient cystic fibrosis, HC: healthy control, AUROC: area under the receiver operating characteristic curves
Table presenting the diagnostic performance for the secretory parameters in detecting pancreatic insufficiency
| Sensitivity | Specificity | Accuracy | Cut-off | ||
|---|---|---|---|---|---|
| MRI | Peak volume (mL) | 1.0 (0.69–1.0) | 1.0 (0.86–1.0) | 1.0 (1.0–1.0) | 30 |
| AUC | 1.0 (0.69–1.0) | 1.0 (0.86–1.0) | 1.0 (1.0–1.0) | 250 | |
| US | Peak area (cm2) | 1.0 (0.69–1.0) | 0.96 (0.78–1) | 1.0 (0.98–1.0) | 2.5 |
| AUC | 1.0 (0.69–1.0) | 0.91 (0.72–0.99) | 0.99 (0.97–1.0) | 30 |
Values in parentheses represent a 95% confidence interval. MRI: magnetic resonance imaging, US: ultrasonography, AUC: area under the curve.