Literature DB >> 29134318

The impact of different peripheral suture techniques on the biomechanical stability in flexor tendon repair.

B Wieskötter1, M Herbort2, M Langer2, M J Raschke2, D Wähnert2,3.   

Abstract

PURPOSE: Flexor tendon repair consists of circumferential peripheral sutures in combination with core sutures to avoid fraying and reduces the exposure of suture material on tendon surface. The peripheral suture adds up to a tenfold increase of the biomechanical stability compared to the core suture alone. The purpose of our study was to determine the most favourable peripheral repair technique for tendon repair.
METHODS: Seventy-two porcine flexor tendons underwent standardized tenotomy and repair using one of the following six methods (n = 12): simple-running (SR), simple-locking (SL), Halsted-mattress (HM), lin-locking (LL), Lembert-mattress (LM), and Silfverskiöld cross-stich (SCS) suture technique. The SL- suture was placed 2 mm; the HM, LM, SC, and LL suture were placed 5 mm from the tendon gap. The SR suture was placed 1, 2, and 3 mm from tendon ends; no additional core suture was applied. For cyclic testing (1000 cycles), elongation was calculated; for load to failure construct stiffness, yield load and maximum load were determined.
RESULTS: The mean cyclic elongation for all tested suture techniques was less than 2 mm; there was no significant difference between the groups regarding elongation as well as yield load. The HM, LM, SCS, and LL suture techniques presented significantly higher maximum loads compared to the SR- and SL-sutures. The 3 mm SR showed significantly higher maximum loads compared to the 2 and 1 mm SR.
CONCLUSIONS: Beside the distance from tendon gap, the type of linkage of the suture material across and beneath the epitendineum is important for biomechanical stability. Simple-running suture is easy to use, even with a slight increase of the distance from tendon gap significantly increases biomechanical strength. For future repairs of flexor tendon injuries, 3 mm stitch length is highly recommended for simple peripheral suture, while the Halsted-mattress suture unites the most important qualities: biomechanically strong, most part of suture material placed epitendinous, and not too complicated to perform.

Entities:  

Keywords:  Biomechanical stability; Flexor tendon repair; Peripheral suture techniques

Mesh:

Year:  2017        PMID: 29134318     DOI: 10.1007/s00402-017-2836-2

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  5 in total

1.  Improving Strength and Quality of Epitendinous Repairs.

Authors:  Angel Farinas; Michael Stephanides; Steven Schneeberger; Alonda Pollins; Nancy Cardwell; Wesley P Thayer
Journal:  Hand (N Y)       Date:  2018-12-05

2.  The single-suture technique for anterior cruciate ligament graft preparation provides similar stability as a three-suture technique: a biomechanical in vitro study in a porcine model.

Authors:  Jan Theopold; Stefan Schleifenbaum; Alexander Georgi; Michael Schmidt; Ralf Henkelmann; Georg Osterhoff; Pierre Hepp
Journal:  Arch Orthop Trauma Surg       Date:  2020-01-24       Impact factor: 3.067

Review 3.  Natural, synthetic and commercially-available biopolymers used to regenerate tendons and ligaments.

Authors:  Behzad Shiroud Heidari; Rui Ruan; Ebrahim Vahabli; Peilin Chen; Elena M De-Juan-Pardo; Minghao Zheng; Barry Doyle
Journal:  Bioact Mater       Date:  2022-04-13

4.  Microsurgical reconstruction affects the outcome in a translational mouse model for Achilles tendon healing.

Authors:  Philipp A Michel; Daniel Kronenberg; Gertje Neu; Josef Stolberg-Stolberg; Andre Frank; Thomas Pap; Martin Langer; Michael Fehr; Michael J Raschke; Richard Stange
Journal:  J Orthop Translat       Date:  2020-05-11       Impact factor: 5.191

5.  Evaluation of biomechanical properties on partial and complete epitendinous suture in human cadaver flexor tendon repair.

Authors:  Thepparat Kanchanathepsak; Wilarat Wairojanakul; Sorasak Suppaphol; Ittirat Watcharananan; Panithan Tuntiyatorn; Tulyapruek Tawonsawatruk
Journal:  J Orthop Surg Res       Date:  2021-08-12       Impact factor: 2.359

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.