Literature DB >> 29131799

Multislice computed tomography assessment of everolimus-eluting Absorb bioresorbable scaffolds in comparison with metallic drug-eluting stents from the ABSORB Japan randomised trial.

Kengo Tanabe1, Jeffrey J Popma, Ken Kozuma, Shigeru Saito, Toshiya Muramatsu, Sunao Nakamura, Atsuo Namiki, Yoshihiro Morino, Nobuhisa Hagiwara, Masaaki Uematsu, Tomohiro Kawasaki, Kenshi Fujii, Patrick W Serruys, Yoshinobu Onuma, Shihwa Ying, Hajime Kusano, Gregg W Stone, Takeshi Kimura.   

Abstract

AIMS: Blooming artefacts limit accurate coronary assessment by multislice computed tomography (MSCT) in metallic stents. We sought to investigate whether bioresorbable vascular scaffolds (BVS) could be better assessed by MSCT. METHODS AND
RESULTS: Among 400 patients in the randomised ABSORB Japan trial, a pre-specified MSCT substudy was performed in 98 patients (103 lesions) in the BVS arm and 49 patients (49 lesions) in the cobalt-chromium everolimus-eluting stent (CoCr-EES) arm at 13 months prior to follow-up angiography. The assessability of BVS by MSCT was superior to that of CoCr-EES (94% versus 67%, p<0.001). Blooming artefacts were the main reason CoCr-EES could not be analysed (29%), while marker artefacts precluded analysis in 1.1% of BVS. In the CoCr-EES arm, non-assessable lesions were more prevalent in segments with 2.5 mm stents compared to 3.0 or 3.5 mm stents (75.0% versus 23.5%, p=0.01), while in the BVS arm image quality was good regardless of the diameter. The in-device minimal lumen diameter by MSCT was smaller than that by QCA with a difference of 0.61 mm in the CoCr-EES arm, vs. only 0.026 mm in the BVS arm.
CONCLUSIONS: The feasibility of MSCT assessment of BVS-treated lesions was greater than that for lesions with CoCr-EES.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29131799     DOI: 10.4244/EIJ-D-17-00716

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  3 in total

Review 1.  Bioresorbable Vascular Scaffolds-Dead End or Still a Rough Diamond?

Authors:  Mateusz P Jeżewski; Michał J Kubisa; Ceren Eyileten; Salvatore De Rosa; Günter Christ; Maciej Lesiak; Ciro Indolfi; Aurel Toma; Jolanta M Siller-Matula; Marek Postuła
Journal:  J Clin Med       Date:  2019-12-07       Impact factor: 4.241

2.  Coronary bioresorbable stents: Non-invasive quantitative evaluation of intra- and juxta-stent plaque composition-A computed tomography longitudinal study.

Authors:  Evguenia Zdanovich; Samer Mansour; Louis-Mathieu Stevens; Charbel Naim; Daniel Juneau; Alexandre Semionov; Carl Chartrand-Lefebvre
Journal:  PLoS One       Date:  2022-10-13       Impact factor: 3.752

3.  Intelligent Algorithm-Based Multislice Spiral Computed Tomography to Diagnose Coronary Heart Disease.

Authors:  Shaowen Tan; Zili Xu
Journal:  Comput Math Methods Med       Date:  2022-01-13       Impact factor: 2.238

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.