Literature DB >> 29131442

Increased rates of atrial fibrillation recurrence following pulmonary vein isolation in overweight and obese patients.

Bhradeev Sivasambu1, Muhammad A Balouch1, Tarek Zghaib1, Rizma J Bajwa1, Jonathan Chrispin1, Ronald D Berger1, Hiroshi Ashikaga1, Saman Nazarian1,2, Joseph E Marine1, Hugh Calkins1, David D Spragg1.   

Abstract

INTRODUCTION: Catheter ablation is common for patients with symptomatic, drug-refractory atrial fibrillation (AF). Obesity is a known risk factor for incident AF. The impact of obesity on AF ablation outcomes is incompletely understood. We sought to determine the impact of elevated body mass index (BMI) on pulmonary vein isolation (PVI) procedural outcomes and associated complications. METHODS AND
RESULTS: We evaluated patients undergoing PVI from 2001 to 2015, dividing them into four groups: normal weight (BMI ≥ 18.5 to < 25), overweight (BMI ≥ 25 to < 30), obese (BMI > 30 to < 40), and morbidly obese (BMI ≥ 40). Demographic and procedural characteristics, complications, and ablation outcomes were compared among groups. A total of 701 patients (146 time-matched controls, 227 overweight, 244 obese, and 84 morbidly obese) with complete demographic, procedural, and follow-up data were included. Increasing BMI correlated positively with HTN, OSA, CHA2 DS2 -VASC score, and persistent AF (P ≤ 0.001 for all associations). Radiofrequency application time and intraprocedural heparin dose increased with BMI (P ≤ 0.001). Arrhythmia recurrence at 1 year was 39.9% in controls, while higher in all high-BMI groups (overweight, 51.3%; obese, 57%; morbidly obese, 58.1 %; P  =  0.007 for all versus controls). Impact of BMI on AF recurrence was not seen in persistent AF patients. Complication rates across groups were similar.
CONCLUSIONS: AF recurrence after catheter ablation is higher in overweight, obese, and morbidly obese patients comparing to normal-weight controls, driven primarily by outcomes differences in paroxysmal AF patients. Complications were not associated with increased BMI.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  atrial fibrillation; body mass index; catheter ablation; obesityzzm321990

Mesh:

Year:  2017        PMID: 29131442     DOI: 10.1111/jce.13388

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  14 in total

1.  Periatrial Fat Quality Predicts Atrial Fibrillation Ablation Outcome.

Authors:  Luisa Ciuffo; Hieu Nguyen; Mateus Diniz Marques; Konstantinos N Aronis; Bhradeev Sivasambu; Henrique D de Vasconcelos; Susumu Tao; David D Spragg; Joseph E Marine; Ronald D Berger; Joao A C Lima; Hugh Calkins; Hiroshi Ashikaga
Journal:  Circ Cardiovasc Imaging       Date:  2019-06-10       Impact factor: 7.792

2.  Impacts of the body size on the left atrial wall thickness and atrial fibrillation recurrence after catheter ablation.

Authors:  Yosuke Nakatani; Tamotsu Sakamoto; Yoshiaki Yamaguchi; Yasushi Tsujino; Naoya Kataoka; Kunihiro Nishida; Koichi Mizumaki; Koichiro Kinugawa
Journal:  Heart Vessels       Date:  2019-02-08       Impact factor: 2.037

3.  Paroxysmal atrial fibrillation recurrence after redo procedure-ablation modality impact.

Authors:  Ivan Zeljkovic; Sven Knecht; Florian Spies; Tobias Reichlin; Stefan Osswald; Michael Kühne; Christian Sticherling
Journal:  J Interv Card Electrophysiol       Date:  2020-01-07       Impact factor: 1.900

4.  Prolonged P-wave duration in sinus rhythm pre-ablation is associated with atrial fibrillation recurrence after pulmonary vein isolation-A systematic review and meta-analysis.

Authors:  Raymond Pranata; Emir Yonas; Rachel Vania
Journal:  Ann Noninvasive Electrocardiol       Date:  2019-04-14       Impact factor: 1.468

5.  Extreme Obesity is Associated with Low Success Rate of Atrial Fibrillation Catheter Ablation.

Authors:  Toshimasa Okabe; Benjamin Buck; Samuel A Hayes; Thura T Harfi; Muhammad R Afzal; Jaret Tyler; Mahmoud Houmsse; Steven J Kalbfleisch; Raul Weiss; John D Hummel; Ralph S Augostini; Emile G Daoud
Journal:  J Atr Fibrillation       Date:  2020-04-30

Review 6.  Impact of body mass index on procedural complications, procedure duration, and radiation dose in patients with atrial fibrillation undergoing radiofrequency ablation: A systematic review and meta-analysis.

Authors:  Menglu Liu; Kaibo Mei; Xiao Liu; Yujie Zhao
Journal:  Clin Cardiol       Date:  2020-06-03       Impact factor: 2.882

7.  Impact of Obesity on Atrial Fibrillation Recurrence Following Stand-Alone Cox Maze IV Procedure.

Authors:  Robert M MacGregor; Ali J Khiabani; Nadia H Bakir; Meghan O Kelly; Samuel C Perez; Hersh S Maniar; Richard B Schuessler; Marc R Moon; Spencer J Melby; Ralph J Damiano
Journal:  Innovations (Phila)       Date:  2021-06-27

8.  Impact of pre-ablation weight loss on the success of catheter ablation for atrial fibrillation.

Authors:  Graham Peigh; Jeremiah Wasserlauf; Kelly Vogel; Rachel M Kaplan; Anna Pfenniger; Daniel Marks; Arjun Mehta; Alexandru B Chicos; Rishi Arora; Susan Kim; Albert Lin; Nishant Verma; Kaustubha D Patil; Bradley P Knight; Rod S Passman
Journal:  J Cardiovasc Electrophysiol       Date:  2021-07-05       Impact factor: 2.942

9.  Are left ventricular ejection fraction and left atrial diameter related to atrial fibrillation recurrence after catheter ablation?: A meta-analysis.

Authors:  Xiao Jin; Jianke Pan; Huanlin Wu; Danping Xu
Journal:  Medicine (Baltimore)       Date:  2018-05       Impact factor: 1.889

10.  Impact of Body Mass Index on the Outcomes of Catheter Ablation of Atrial Fibrillation: A European Observational Multicenter Study.

Authors:  Rui Providência; Pedro Adragão; Carlo de Asmundis; Julian Chun; Gianbattista Chierchia; Pascal Defaye; Frédéric Anselme; Antonio Creta; Pier D Lambiase; Boris Schmidt; Shaojie Chen; Diogo Cavaco; Ross J Hunter; João Carmo; Stephane Combes; Shohreh Honarbakhsh; Nicolas Combes; Maria João Sousa; Zeynab Jebberi; Jean-Paul Albenque; Serge Boveda
Journal:  J Am Heart Assoc       Date:  2019-10-04       Impact factor: 5.501

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.