Literature DB >> 29127431

Effect of Cornea Preservation Time on Success of Descemet Stripping Automated Endothelial Keratoplasty: A Randomized Clinical Trial.

George O Rosenwasser1, Loretta B Szczotka-Flynn2,3, Allison R Ayala4, Wendi Liang4, Anthony J Aldave5, Steven P Dunn6, Tyrone McCall7, Lisa C Navarro8, Sudeep Pramanik9, Kevin W Ross10, R Doyle Stulting11, Mark A Terry12, Elmer Y Tu13, David D Verdier14, Craig Kollman4, Robin L Gal4, Roy W Beck4, Jonathan H Lass2,3.   

Abstract

Importance: Demonstrating that success of Descemet stripping automated endothelial keratoplasty is similar across donor cornea preservation times (PTs) could increase the donor pool. Objective: To determine whether the 3-year rate of graft success using corneal donor tissue preserved 8 to 14 days is noninferior to that of donor tissue preserved 7 days or less. Design, Setting, and Participants: A multicenter, double-masked, randomized noninferiority clinical trial was conducted from April 16, 2012, to June 5, 2017, at 40 clinical sites (70 surgeons) in the United States, with donor corneas provided by 23 US eye banks. A total of 1090 individuals (1330 study eyes) underwent Descemet stripping automated endothelial keratoplasty (1255 eyes [94.4%] for Fuchs endothelial corneal dystrophy). Interventions: Descemet stripping automated endothelial keratoplasty with random assignment of a donor cornea with a PT of 7 days or less (0-7d PT) or 8 to 14 days (8-14d PT). Main Outcomes and Measures: Graft success at 3 years.
Results: Of the 1090 participants (1330 study eyes; 60.2% women and 39.8% men; median age at enrollment, 70 years [range, 42-90 years]), the 3-year cumulative probability of graft success was 95.3% (95% CI, 93.6%-96.9%) in the 0-7d PT group and 92.1% (95% CI, 89.9%-94.2%) in the 8-14d PT group (difference, 3.2%). The upper limit of the 1-sided 95% CI on the difference was 5.4%, exceeding the prespecified noninferiority limit of 4%. The difference was mostly owing to more primary donor failures in the 8-14d PT group, with the conditional probability of failure after the first month being 2.4% in the 0-7d PT group and 3.1% in the 8-14d PT group. In preplanned secondary analyses, longer PT was associated with a lower rate of graft success (unadjusted hazard ratio for graft failure per additional day of PT, 1.10; 95% CI, 1.03-1.18; P = .008 [PT analyzed as days]), with success rates of 96.5% (95% CI, 92.3%-98.4%) for PT of 4 days or less, 94.9% (95% CI, 92.5%-96.6%) for PT of 5 to 7 days, 93.8% (95% CI, 91.0%-95.8%) for PT of 8 to 11 days, and 89.3% (95% CI, 84.4%-92.7%) for PT of 12 to 14 days (P = .01 [PT analyzed as categorical variable]). Conclusions and Relevance: The 3-year success rate in eyes undergoing Descemet stripping automated endothelial keratoplasty was high irrespective of PT. However, the study was unable to conclude that the success rate with donor corneas preserved 8 to 14 days was similar to that of corneas preserved 7 days or less with respect to the prespecified noninferiority limit. Although longer PT was associated with a lower success rate, the difference in rates was small when PT was less than 12 days.

Entities:  

Mesh:

Year:  2017        PMID: 29127431      PMCID: PMC6583547          DOI: 10.1001/jamaophthalmol.2017.4989

Source DB:  PubMed          Journal:  JAMA Ophthalmol        ISSN: 2168-6165            Impact factor:   7.389


  14 in total

1.  Corneal endothelial cell therapy: feasibility of cell culture from corneas stored in organ culture.

Authors:  Zhiguo He; Naoki Okumura; Masakazu Sato; Yuya Komori; Makiko Nakahara; Philippe Gain; Noriko Koizumi; Gilles Thuret
Journal:  Cell Tissue Bank       Date:  2021-04-16       Impact factor: 1.522

2.  Donor, Recipient, and Operative Factors Associated with Graft Success in the Cornea Preservation Time Study.

Authors:  Mark A Terry; Anthony J Aldave; Loretta B Szczotka-Flynn; Wendi Liang; Allison R Ayala; Maureen G Maguire; Christopher Croasdale; Yassine J Daoud; Steven P Dunn; Caroline K Hoover; Marian S Macsai; Thomas F Mauger; Sudeep Pramanik; George O D Rosenwasser; Jennifer Rose-Nussbaumer; R Doyle Stulting; Alan Sugar; Elmer Y Tu; David D Verdier; Sonia H Yoo; Jonathan H Lass
Journal:  Ophthalmology       Date:  2018-08-09       Impact factor: 12.079

3.  Factors influencing endothelial cell density of corneas for transplantation.

Authors:  Thatiane Lima Sampaio; Isabela Pereira Rodrigues; Micheline Borges Lucas Cresta; Anna Cláudia de Oliveira Queiroz; Thayssa Neiva da Fonseca Victer; Daniela Ferreira Salomão Pontes; Wildo Navegantes de Araújo; Sônia Nair Báo; Maria Regina Catai Chalita
Journal:  Cell Tissue Bank       Date:  2020-11-09       Impact factor: 1.522

4.  Effect of Graft Attachment Status and Intraocular Pressure on Descemet Stripping Automated Endothelial Keratoplasty Outcomes in the Cornea Preservation Time Study.

Authors:  Anthony J Aldave; Mark A Terry; Loretta B Szczotka-Flynn; Wendi Liang; Allison R Ayala; Maureen G Maguire; Robert C O'Brien; Beth Ann Benetz; John E Bokosky; Steven P Dunn; Thomas E Gillette; Kristin M Hammersmith; David R Hardten; Bennie H Jeng; Marc F Jones; Richard L Lindstrom; Kenneth J Maverick; Verinder S Nirankari; Matthew S Oliva; Irving M Raber; Christopher J Rapuano; George O D Rosenwasser; Kevin W Ross; John W Seedor; Neda Shamie; Christopher G Stoeger; Shachar Tauber; Woodford S Van Meter; David D Verdier; Jonathan H Lass
Journal:  Am J Ophthalmol       Date:  2019-03-06       Impact factor: 5.258

5.  Donor, Recipient, and Operative Factors Associated With Increased Endothelial Cell Loss in the Cornea Preservation Time Study.

Authors:  Jonathan H Lass; Beth Ann Benetz; Sanjay V Patel; Loretta B Szczotka-Flynn; Robert O'Brien; Allison R Ayala; Maureen G Maguire; Yassine J Daoud; Mark A Greiner; Sadeer B Hannush; W Barry Lee; Thomas F Mauger; Harry J Menegay; Mark D Mifflin; Michael B Raizman; Jennifer Rose-Nussbaumer; Robert L Schultze; Gregory A Schmidt; Alan Sugar; Mark A Terry; David D Verdier
Journal:  JAMA Ophthalmol       Date:  2019-02-01       Impact factor: 7.389

6.  Incidence and Outcomes of Positive Donor Rim Cultures and Infections in the Cornea Preservation Time Study.

Authors:  Shahzad I Mian; Anthony J Aldave; Elmer Y Tu; Brandon D Ayres; Bennie H Jeng; Marian S Macsai; Michael L Nordlund; Jeffrey G Penta; Sudeep Pramanik; Loretta B Szczotka-Flynn; Allison R Ayala; Wendi Liang; Maureen G Maguire; Jonathan H Lass
Journal:  Cornea       Date:  2018-09       Impact factor: 2.651

7.  Factors Associated With Graft Rejection in the Cornea Preservation Time Study.

Authors:  R Doyle Stulting; Jonathan H Lass; Mark A Terry; Beth Ann Benetz; Nathan J Cohen; Allison R Ayala; Maureen G Maguire; Christopher Croasdale; Yassine J Daoud; Steven P Dunn; Kenneth M Goins; Pankaj C Gupta; Marian S Macsai; Shahzad I Mian; Sudeep Pramanik; Jennifer Rose-Nussbaumer; Jonathan C Song; Walter J Stark; Alan Sugar; David D Verdier; Loretta B Szczotka-Flynn
Journal:  Am J Ophthalmol       Date:  2018-10-09       Impact factor: 5.258

Review 8.  Corneal Donation: Current Guidelines and Future Direction.

Authors:  Majid Moshirfar; Varshini S Odayar; Shannon E McCabe; Yasmyne C Ronquillo
Journal:  Clin Ophthalmol       Date:  2021-07-12

9.  Solubilized ubiquinol for preserving corneal function.

Authors:  Youssef W Naguib; Sanjib Saha; Jessica M Skeie; Timothy Acri; Kareem Ebeid; Somaya Abdel-Rahman; Sandeep Kesh; Gregory A Schmidt; Darryl Y Nishimura; Jeffrey A Banas; Min Zhu; Mark A Greiner; Aliasger K Salem
Journal:  Biomaterials       Date:  2021-05-01       Impact factor: 15.304

10.  Comparison of Donor Cornea Endothelial Cell Density Determined by Eye Banks and by a Central Reading Center in the Cornea Preservation Time Study.

Authors:  Beth Ann Benetz; Christopher G Stoeger; Sanjay V Patel; Robert C OʼBrien; Loretta B Szczotka-Flynn; Allison R Ayala; Maureen G Maguire; Harry J Menegay; Peter Bedard; Jameson M Clover; Pankaj C Gupta; Kristen E McCoy; Jonathan C Song; Jonathan H Lass
Journal:  Cornea       Date:  2019-04       Impact factor: 3.152

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.