Literature DB >> 29125215

Additive Manufacturing: A Comparative Analysis of Dimensional Accuracy and Skin Texture Reproduction of Auricular Prostheses Replicas.

Alexey Unkovskiy1, Sebastian Spintzyk2, Detlef Axmann1, Eva-Maria Engel1, Heiner Weber1, Fabian Huettig1.   

Abstract

PURPOSE: The use of computer-aided design/computer-aided manufacturing (CAD/CAM) and additive manufacturing in maxillofacial prosthetics has been widely acknowledged. Rapid prototyping can be considered for manufacturing of auricular prostheses. Therefore, so-called prostheses replicas can be fabricated by digital means. The objective of this study was to identify a superior additive manufacturing method to fabricate auricular prosthesis replicas (APRs) within a digital workflow.
MATERIALS AND METHODS: Auricles of 23 healthy subjects (mean age of 37.8 years) were measured in vivo with respect to an anthropometrical protocol. Landmarks were volumized with fiducial balls for 3D scanning using a handheld structured light scanner. The 3D CAD dataset was postprocessed, and the same anthropometrical measurements were made in the CAD software with the digital lineal. Each CAD dataset was materialized using fused deposition modeling (FDM), selective laser sintering (SLS), and stereolithography (SL), constituting 53 APR samples. All distances between the landmarks were measured on the APRs. After the determination of the measurement error within the five data groups (in vivo, CAD, FDM, SLS, and SL), the mean values were compared using matched pairs method. To this, the in vivo and CAD dataset were set as references. Finally, the surface structure of the APRs was qualitatively evaluated with stereomicroscopy and profilometry to ascertain the level of skin detail reproduction.
RESULTS: The anthropometrical approach showed drawbacks in measuring the protrusion of the ear's helix. The measurement error within all groups of measurements was calculated between 0.20 and 0.28 mm, implying a high reproducibility. The lowest mean differences of 53 produced APRs were found in FDM (0.43%) followed by SLS (0.54%) and SL (0.59%)--compared to in vivo, and again in FDM (0.20%) followed by SL (0.36%) and SLS (0.39%)--compared to CAD. None of these values exceed the threshold of clinical relevance (1.5%); however, the qualitative evaluation revealed slight shortcomings in skin reproduction for all methods: reproduction of skin details exceeding 0.192 mm in depth was feasible.
CONCLUSION: FDM showed the superior dimensional accuracy and best skin surface reproduction. Moreover, digital acquisition and CAD postprocessing seem to play a more important role in the outcome than the additive manufacturing method used.
© 2017 by the American College of Prosthodontists.

Entities:  

Keywords:  Auricular prosthesis; digital workflow; facial prosthesis; fused deposition modeling; maxillofacial rehabilitation; rapid prototyping

Mesh:

Year:  2017        PMID: 29125215     DOI: 10.1111/jopr.12681

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  6 in total

1.  Intraoperative integration of structured light scanning for automatic tissue classification: a feasibility study.

Authors:  Brandon Chan; John F Rudan; Parvin Mousavi; Manuela Kunz
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-03-06       Impact factor: 2.924

Review 2.  Development and Application of Three-Dimensional Bioprinting Scaffold in the Repair of Spinal Cord Injury.

Authors:  Dezhi Lu; Yang Yang; Pingping Zhang; Zhenjiang Ma; Wentao Li; Yan Song; Haiyang Feng; Wenqiang Yu; Fuchao Ren; Tao Li; Hong Zeng; Jinwu Wang
Journal:  Tissue Eng Regen Med       Date:  2022-06-29       Impact factor: 4.169

Review 3.  The cutting edge of customized surgery: 3D-printed models for patient-specific interventions in otology and auricular management-a systematic review.

Authors:  Adam Omari; Martin Frendø; Mads Sølvsten Sørensen; Steven Arild Wuyts Andersen; Andreas Frithioff
Journal:  Eur Arch Otorhinolaryngol       Date:  2022-02-15       Impact factor: 2.503

4.  Dimensional Accuracy and Mechanical Properties of Chopped Carbon Reinforced Polymers Produced by Material Extrusion Additive Manufacturing.

Authors:  Evren Yasa; Kıvılcım Ersoy
Journal:  Materials (Basel)       Date:  2019-11-25       Impact factor: 3.623

5.  Osseointegrated implant-retained auricular prosthesis constructed using cone-beam computed tomography and a prosthetically driven digital workflow: a case report.

Authors:  Daniel Domingue; Nathan Cory Glenn; Allison Vest; James R White
Journal:  Clin Case Rep       Date:  2020-11-17

6.  Compatibility of a Silicone Impression/Adhesive System to FDM-Printed Tray Materials-A Laboratory Peel-off Study.

Authors:  Yichen Xu; Alexey Unkovskiy; Felix Klaue; Frank Rupp; Juergen Geis-Gerstorfer; Sebastian Spintzyk
Journal:  Materials (Basel)       Date:  2018-10-07       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.