UV Disinfection of Wastewater and Combined Sewer Overflows.

John Gibson1, Jennifer Drake2, Bryan Karney3.   

Abstract

Municipal wastewater contains bacteria, viruses, and other pathogens that adversely affect the environment, human health, and economic activity. One way to mitigate these effects is a final disinfection step using ultraviolet light (UVL). The advantages of UVL disinfection, when compared to the more traditional chlorine, include no chlorinated by-products, no chemical residual, and relatively compact size. The design of most UV reactors is complex. It involves lamp selection, power supply design, optics, and hydraulics. In general, medium pressure lamps are more compact, powerful, and emit over a wider range of light than the more traditional low pressure lamps. Low pressure lamps, however, may be electrically more efficient. In UV disinfection, the fraction of surviving organisms (e.g. E. coli) will decrease exponentially with increasing UV dose. However, the level of disinfection that can be achieved is often limited by particle-associated organisms. Efforts to remove or reduce the effects of wastewater particles will often improve UV disinfection effectiveness. Regrowth, photoreactivation, or dark repair after UV exposure are sometimes cited as disadvantages of UV disinfection. Research is continuing in this area, however there is little evidence that human pathogens can photoreactivate in environmental conditions, at doses used in wastewater treatment. The UV disinfection of combined sewer overflows, a form of wet weather pollution, is challenging and remains largely at the research phase. Pre-treatment of combined sewer overflows (CSOs) with a cationic polymer to induce fast settling, and a low dose of alum to increase UV transmittance, has shown promise at the bench scale.

Entities:  

Keywords:  Alum; Disinfection; Indicator organisms; Lamp selection; Photoreactivation

Mesh:

Substances:

Year:  2017        PMID: 29124707     DOI: 10.1007/978-3-319-56017-5_22

Source DB:  PubMed          Journal:  Adv Exp Med Biol        ISSN: 0065-2598            Impact factor:   2.622


  4 in total

1.  Sodium hypochlorite disinfection of SARS-CoV-2 spiked in water and municipal wastewater.

Authors:  Justin Greaves; Robert J Fischer; Marlee Shaffer; Aaron Bivins; Myndi G Holbrook; Vincent J Munster; Kyle Bibby
Journal:  Sci Total Environ       Date:  2021-10-08       Impact factor: 7.963

Review 2.  Review of Antimicrobial Resistance in Wastewater in Japan: Current Challenges and Future Perspectives.

Authors:  Hiroaki Baba; Masateru Nishiyama; Toru Watanabe; Hajime Kanamori
Journal:  Antibiotics (Basel)       Date:  2022-06-24

Review 3.  Challenges to detect SARS-CoV-2 on environmental media, the need and strategies to implement the detection methodologies in wastewaters.

Authors:  Javier E Sanchez-Galan; Grimaldo Ureña; Luis F Escovar; Jose R Fabrega-Duque; Alexander Coles; Zohre Kurt
Journal:  J Environ Chem Eng       Date:  2021-06-29

4.  Inactivation of airborne bacteria using different UV sources: Performance modeling, energy utilization, and endotoxin degradation.

Authors:  Can Wang; Siyi Lu; Zhiwei Zhang
Journal:  Sci Total Environ       Date:  2018-11-20       Impact factor: 7.963

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.