Literature DB >> 29123998

Feasibility of Dentascan in planning of implant surgery in posterior maxilla and mandible.

Siddhartha Chandel1, Nishi Singh2, Amiya Agrawal3, Harmurti Singh4, H Nandakumar5.   

Abstract

OBJECTIVES: The present evaluate the feasibility of Computed tomography (Dentascan), in assessment of the implant site in posterior maxilla & mandible.
MATERIAL AND METHODS: data of total 11 patients with 20 implant sites were involved in the present study. Out of the 20 implant sites selected 10 were in posterior maxilla and 10 in posterior mandible. All the patients were routinely examined by panoramic radiography and CT. All images obtained i.e., conventional panoramic radiograph, and film based Dentascan MPR- CT images were evaluated for the detectability of mandibular canal at the mental foramen, 1 cm, 2 cm, and 3 cm posterior to mental foramen. The judgments were then compared by using the four point grading score.
RESULTS: Both the statistical analysis and radiographic observation showed that Dentascan MPR CT gives significantly clearer images at the mental foramen and 1 cm, 2 cm , 3 cm posterior to it. Dentascan also provides significantly better visualization of the vital structures along with the bone density. The panoramic and Dentascan MPR CT images did not show a significant difference in visualization of the crest of alveolar ridge in both maxillary as well as the mandibular arch.
CONCLUSION: The Dentascan MPR- CT images revealed significantly clearer images as well as better visualization of the vital structures than conventional panoramic radiography. Apart from providing clearer images Dentascan also gives the buccopalatal/buccolingual dimension at the implant site, along with the density of the available bone.

Entities:  

Keywords:  Dentascan; Implants; Panoramic radiography; Posterior maxilla and mandible

Year:  2017        PMID: 29123998      PMCID: PMC5670300          DOI: 10.1016/j.jobcr.2017.03.001

Source DB:  PubMed          Journal:  J Oral Biol Craniofac Res        ISSN: 2212-4268


  12 in total

1.  A case for routine computed tomography imaging of the dental alveolus before implant placement.

Authors:  R A Kraut
Journal:  J Oral Maxillofac Surg       Date:  2001-01       Impact factor: 1.895

Review 2.  Why do dental implants fail? Part I.

Authors:  A S el Askary; R M Meffert; T Griffin
Journal:  Implant Dent       Date:  1999       Impact factor: 2.454

3.  Validation of spiral computed tomography for dental implants.

Authors:  M G Cavalcanti; J Yang; A Ruprecht; M W Vannier
Journal:  Dentomaxillofac Radiol       Date:  1998-11       Impact factor: 2.419

4.  Bone density assessments of dental implant sites: 1. Quantitative computed tomography.

Authors:  Masih Shahlaie; Bernard Gantes; Eloy Schulz; Matt Riggs; Max Crigger
Journal:  Int J Oral Maxillofac Implants       Date:  2003 Mar-Apr       Impact factor: 2.804

5.  A survey of radiographic prescription in dental implant assessment.

Authors:  C E Sakakura; J A N D Morais; L C M Loffredo; G Scaf
Journal:  Dentomaxillofac Radiol       Date:  2003-11       Impact factor: 2.419

6.  Location of the mandibular canal: comparison of macroscopic findings, conventional radiography, and computed tomography.

Authors:  B Klinge; A Petersson; P Maly
Journal:  Int J Oral Maxillofac Implants       Date:  1989       Impact factor: 2.804

7.  Geometric considerations in the transition from two-dimensional to three-dimensional treatment planning.

Authors:  Krishna C Yeshwant; Petra Thurmüller; Edward B Seldin
Journal:  Atlas Oral Maxillofac Surg Clin North Am       Date:  2005-03

8.  A comparison of panoramic radiography with computed tomography in the planning of implant surgery.

Authors:  H Tal; O Moses
Journal:  Dentomaxillofac Radiol       Date:  1991-02       Impact factor: 2.419

9.  Measurements of distances related to the mandibular canal in radiographs.

Authors:  C Lindh; A Petersson; B Klinge
Journal:  Clin Oral Implants Res       Date:  1995-06       Impact factor: 5.977

10.  Interpretation of linear and computed tomograms in the assessment of implant recipient sites.

Authors:  A D Todd; M E Gher; G Quintero; A C Richardson
Journal:  J Periodontol       Date:  1993-12       Impact factor: 6.993

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.