Literature DB >> 29122117

Plate versus intramedullary fixation of two-part and multifragmentary displaced midshaft clavicle fractures - a long-term analysis.

Gareth Chan1, Zelimir Korac2, Matija Miletic2, Dinko Vidovic3, Joideep Phadnis1, Bore Bakota4.   

Abstract

INTRODUCTION: Surgical fixation of displaced midshaft clavicle fractures is predominantly achieved with intramedullary (IM) or plate fixation. Both techniques have potential pitfalls: plate fixation involves greater periosteal stripping and protuberance of the implant, whereas IM fixation may be associated with implant-related complications, such as migration or skin irritation, which may lead to further surgery for implant removal. The aim of this study was to compare these two methods in simple (Robinson 2b.1) and multifragmentary (Robinson 2b.2) displaced midshaft clavicle fractures.
METHODS: A total of 133 consecutive patients who underwent surgical fixation for a displaced midshaft clavicle fracture with either IM fixation using a 2.5-mm Kirschner wire or plate fixation using an 8-hole Dynamic Compression Plate (DCP) were retrospectively reviewed. Follow-up was a minimum of 1 year. The patients were allocated into two injury groups: displaced simple 2-part fractures (64 IM vs. 16 DCP) and displaced multifragmentary fractures (27 IM vs. 26 DCP). The major observed outcome measures were: infection rate, non-union rate, reoperation rate and postoperative range of motion (ROM).
RESULTS: Rates of non-union for displaced 2-part fractures were 2/64 (3.13%) with IM fixation and 0/16 (0.00%) with plate fixation (p = 0.477). For displaced multifragmentary fractures, rates of non-union were 2/27 (7.41%) with IM fixation and 0/26 (0.00%) with plate fixation (p = 0.161). No significant difference was observed between the two fixation modalities in patient-reported time to regain ROM on the injured side for displaced 2-part fractures (p = 0.129) and displaced multifragmentary fractures (p = 0.070). Deep infection rate was zero (p = 1.000) overall in the study, and reoperation rate for IM and plate fixation, respectively, was 3.13% and 6.25% in the Robinson 2b.1 group (p = 0.559) and 7.41% and 7.69% in the Robinson 2b.2 group (p = 0.969).
CONCLUSION: IM fixation of displaced midshaft clavicle fractures (Robinson 2b.1) has an equivalent non-union rate to plate fixation and similarly low complication and reoperation rates. For displaced midshaft multifragmentary clavicle fractures (Robinson 2b.2), the higher non-union rates observed with IM fixation leads us to recommend consideration of plate fixation for Robinson 2b.2 fractures.
© 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  K-wire; Kirschner wire; clavicle; complications; fracture; intramedullary fixation; midshaft; non-union; plate fixation; plate osteosynthesis

Mesh:

Year:  2017        PMID: 29122117     DOI: 10.1016/S0020-1383(17)30734-9

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  2 in total

1.  Comparison of the Effectiveness of Simple Plate Fixation and Plate Combined with Local Fixation of Broken Ends in the Treatment of Oblique Fracture of Midshaft Clavicle.

Authors:  Gong-Ming Gao; Yi Zhang; Hai-Bo Li; Lu-Ming Nong; Xin-Die Zhou; Wei Jiang; Long Han
Journal:  Orthop Surg       Date:  2022-05-23       Impact factor: 2.279

2.  Plate fixation versus intramedullary nail or Knowles pin fixation for displaced midshaft clavicle fractures: A meta-analysis of randomized controlled trials.

Authors:  Lang Li; Xiaodong Yang; Fei Xing; Jun Jiang; Xueyang Tang
Journal:  Medicine (Baltimore)       Date:  2020-09-25       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.