Literature DB >> 29120715

New pinhole sulcus implant for the correction of irregular corneal astigmatism.

Claudio C Trindade1, Bruno C Trindade2, Fernando C Trindade2, Liliana Werner2, Robert Osher2, Marcony R Santhiago2.   

Abstract

PURPOSE: To evaluate the effect on visual acuity of the implantation of a new intraocular pinhole device (Xtrafocus) in cases of irregular corneal astigmatism with significant visual impairment.
SETTING: University of São Paulo, São Paulo, Brazil.
DESIGN: Prospective case series.
METHODS: Pseudophakic eyes of patients with irregular corneal astigmatism were treated with the pinhole device. The causes of irregular corneal astigmatism were keratoconus, post radial keratotomy (RK), post-penetrating keratoplasty (PKP), and traumatic corneal laceration. The device was implanted in the ciliary sulcus in a piggyback configuration to minimize the effect of corneal aberrations. Preoperative and postoperative visual parameters were compared. The main outcome variables were manifest refraction, uncorrected and corrected distance and near visual acuities, subjective patient satisfaction, and intraoperative and postoperative adverse events and complications.
RESULTS: Twenty-one patients (ages 35 to 85 years) were included. There was statistically significant improvement in uncorrected and corrected (CDVA) distance visual acuities. The median CDVA improved from 20/200 (range 20/800 to 20/60) preoperatively to 20/50 (range 20/200 to 20/20) in the first month postoperatively and remained stable over the following months. Manifest refraction remained unchanged, while a subjective visual performance questionnaire revealed perception of improvement in all the tested working distances. No major complication was observed. One case presented with decentration of the device, which required an additional surgical intervention.
CONCLUSIONS: The intraocular pinhole device performed well in patients with irregular astigmatism caused by keratoconus, RK, PKP, and traumatic corneal laceration. There was marked improvement in visual function, with high patient satisfaction.
Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 29120715     DOI: 10.1016/j.jcrs.2017.09.014

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Persistent troublesome floaters necessitating the explantation of XtraFocus Pinhole IOL (Morcher).

Authors:  Prateek Agarwal; Samuel Edward Navon
Journal:  BMJ Case Rep       Date:  2019-04-08

2.  Xtra focus pinhole IOL (Morchers GMBH) a novel approach to tackle irregular astigmatism and large pupillary defects with a single step surgery.

Authors:  Prateek Agarwal; Samuel Edward Navon
Journal:  BMJ Case Rep       Date:  2019-04-03

3.  A pinhole implant to correct postoperative residual refractive error in an RK cataract patient.

Authors:  Hyeck-Soo Son; Ramin Khoramnia; Christian Mayer; Grzegorz Labuz; Timur M Yildirim; Gerd U Auffarth
Journal:  Am J Ophthalmol Case Rep       Date:  2020-08-20

4.  Implantation of a Small Aperture Intraocular Lens in Eyes with Irregular Corneas and Higher Order Aberrations.

Authors:  Fabrizio Franco; Marco Branchetti; Lidia Vicchio; Federica Serino; Marco Piergentili; Vito Spagnuolo; Francesca Santoro; Gianni Virgili; Fabrizio Giansanti
Journal:  J Ophthalmic Vis Res       Date:  2022-08-15

Review 5.  Review of surgical devices using small aperture optics.

Authors:  Robert Edward T Ang; Michelle Marie Q Araneta; Emerson M Cruz
Journal:  Taiwan J Ophthalmol       Date:  2022-01-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.