Literature DB >> 29119575

Occurrence of hemolytic reactions on the same day as immune globulin product administrations during 2008 to 2014.

Gayathri Sridhar1, Bola F Ekezue1, Hector S Izurieta2, Richard A Forshee2, Nandini Selvam1, Paul D Mintz2, Steven A Anderson2, Mikhail D Menis2.   

Abstract

BACKGROUND: Hemolytic reactions (HRs) are rare serious adverse events after immune globulin (IG) use. Our large claims-based study evaluated occurrence of same-day hemolysis after administration of different IG products and potential risk factors, during the 2008 to 2014 study period. STUDY DESIGN AND METHODS: We conducted a retrospective cohort study using a large commercial administrative database. The study included individuals exposed to IG products as identified by procedure codes. HRs were ascertained using ICD-9-CM diagnosis codes. Unadjusted same-day hemolysis rates (per 1000 persons) were estimated overall, by age, sex, and IG products. Multivariable regression analyses were used to evaluate potential risk factors.
RESULTS: Of 20,440 persons exposed, 211 (10.3 per 1000) had same-day HRs. The median numbers of doses for IG users with versus without same-day hemolysis were one and six, respectively. The unadjusted product-specific HR rates ranged from 1.92 for subcutaneous product Hizentra to 17.99 for intravenous Octagam. The multivariable regression analyses showed significantly increased same-day HR risk in males and in IG users with histories of hemolysis, pneumonia, and hereditary hemolytic anemias. Compared to Gammagard Liquid, significantly elevated overall hemolysis risk was identified with Octagam (odds ratio, 2.36; 95% confidence interval, 1.04-5.35), using Firth's method to account for small sample size bias.
CONCLUSION: The study showed variation in the same-day IG-related hemolysis by age, sex, and IG products administered. The results suggest importance of underlying health conditions, especially prior hemolysis, and first IG product dose. Differences in HR occurrence may also be explained by product manufacturing processes, indications, routes, and rates of administration, which warrant further investigation.
© 2017 AABB.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29119575     DOI: 10.1111/trf.14384

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  3 in total

Review 1.  Incidence and risk factors for intravenous immunoglobulin-related hemolysis: A systematic review of clinical trial and real-world populations.

Authors:  Hillary Cuesta; Ibrahim El Menyawi; Alphonse Hubsch; Liane Hoefferer; Orell Mielke; Susie Gabriel; Amgad Shebl
Journal:  Transfusion       Date:  2022-08-02       Impact factor: 3.337

2.  Isoagglutinin reduction in intravenous immunoglobulin (IgPro10, Privigen) by specific immunoaffinity chromatography reduces its reporting rates of hemolytic reactions: an analysis of spontaneous adverse event reports.

Authors:  Amgad Shebl; Susie Gabriel; Kristy Van Dinther; Alphonse Hubsch; John-Philip Lawo; Liane Hoefferer; Susan Welsh
Journal:  Transfusion       Date:  2020-05-14       Impact factor: 3.157

3.  Anti-A/B isoagglutinin reduction in an intravenous immunoglobulin product and risk of hemolytic anemia: a hospital-based cohort study.

Authors:  Christopher Wallenhorst; Ami Patel; Amgad Shebl; Alphonse Hubsch; Toby L Simon; Carlos Martinez
Journal:  Transfusion       Date:  2020-06-02       Impact factor: 3.157

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.