Jan Heckmann1, Veit Sturm1, Klara Landau2, Béla Török1. 1. Augenklinik, Kantonsspital St. Gallen, Schweiz. 2. Augenklinik Universitätsspital Zürich, Universität Zürich, Schweiz.
Abstract
BACKGROUND: Evaluation of a new method for cyclofusion measurement. PATIENTS AND METHODS: The maximal incyclofusion and excyclofusion tolerated of 20 normal subjects (15 females, mean age 36 ± 9.9 years) were measured by computer-generated dynamic random-dot stereograms (DRDS). Subjects had to detect the orientation of only binocularly visible Landolt C stimuli randomly presented with a 3-D monitor. Both eyes were separately stimulated with shutter glasses. The DRDS-pattern projected to the left and right eye were rotated in the opposite direction in 0.5° steps. In 10 subjects, cyclofusion measurements were repeated. RESULTS: Incylofusional amplitudes were between 2.5° and 6°, excyclofusional amplitudes measured between 3° and 5.5°. Mean incyclofusion was 3.71° (SD 0.82) and mean excyclofusion measured 4.24° (SD 0.73). Repeated measurements of incyclofusion and excyclofusion in the same subject demonstrated a difference of about 0.5° (0.55° for incyclofusion, 0.45° for excyclofusion). CONCLUSIONS: The DRDS Landolt C method provided a reliable assessment with good reproducibility of cyclofusion in healthy subjects with only binocularly perceivable objects. Our cyclofusional capabilities were slightly higher than those received with dissociating 2D measurements. Georg Thieme Verlag KG Stuttgart · New York.
BACKGROUND: Evaluation of a new method for cyclofusion measurement. PATIENTS AND METHODS: The maximal incyclofusion and excyclofusion tolerated of 20 normal subjects (15 females, mean age 36 ± 9.9 years) were measured by computer-generated dynamic random-dot stereograms (DRDS). Subjects had to detect the orientation of only binocularly visible Landolt C stimuli randomly presented with a 3-D monitor. Both eyes were separately stimulated with shutter glasses. The DRDS-pattern projected to the left and right eye were rotated in the opposite direction in 0.5° steps. In 10 subjects, cyclofusion measurements were repeated. RESULTS: Incylofusional amplitudes were between 2.5° and 6°, excyclofusional amplitudes measured between 3° and 5.5°. Mean incyclofusion was 3.71° (SD 0.82) and mean excyclofusion measured 4.24° (SD 0.73). Repeated measurements of incyclofusion and excyclofusion in the same subject demonstrated a difference of about 0.5° (0.55° for incyclofusion, 0.45° for excyclofusion). CONCLUSIONS: The DRDS Landolt C method provided a reliable assessment with good reproducibility of cyclofusion in healthy subjects with only binocularly perceivable objects. Our cyclofusional capabilities were slightly higher than those received with dissociating 2D measurements. Georg Thieme Verlag KG Stuttgart · New York.
Authors: Antony Arokiadass Baskaran; Tanuja Britto; Sundaresan Rajkumar; Philip A Thomas; C A Nelson Jesudasan Journal: Indian J Ophthalmol Date: 2019-05 Impact factor: 1.848