PURPOSE: To establish whether average refractive overcorrection or undercorrection of corneal astigmatism based on the orientation (rule) of the astigmatism occurs if toric intraocular lenses (IOLs) are calculated on the basis of anterior corneal measurements in eyes requiring toric IOL cylinder power of 2.50 diopters (D) or greater.
METHODS: One hundred thirteen consecutive eyes with anterior corneal keratometric astigmatism requiring IOL cylinder power of 2.50 D or greater underwent phacoemulsification with IOL powers calculated using anterior corneal curvature data alone. Eyes were grouped as either "with-the-rule" (WTR) or "against-the-rule" (ATR) on the basis of the steep anterior corneal meridian. Targeted and achieved astigmatic outcomes were compared. The main outcome measure was the postoperative refractive astigmatic prediction error.
RESULTS: A mean overcorrection occurred in anterior WTR eyes of 0.16 ± 0.57 D and a mean undercorrection of ATR eyes of -0.14 ± 0.53 D. These were significantly different from the ideal value of zero (WTR: P = .04, ATR: P = .05). Although statistically significant, the effect sizes of these prediction errors were 0.40 for WTR and 0.36 for ATR and the error values fell below a clinically significant value of 0.25 D.
CONCLUSIONS: In eyes requiring toric IOLs of cylinder power 2.50 D or greater, an overcorrection occurs in anterior WTR eyes and an undercorrection in ATR eyes. This probable posterior corneal astigmatism effect is not clinically significant. IOL cylinder powers are sufficiently accurately calculated using unadjusted anterior keratometry values in these eyes. [J Refract Surg. 2017;33(11):730-734.]. Copyright 2017, SLACK Incorporated.

Entities:  

Mesh:

Year:  2017        PMID: 29117411     DOI: 10.3928/1081597X-20170829-03

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  3 in total

1.  Impact of measured total keratometry versus anterior keratometry on the refractive outcomes of the AT TORBI 709-MP toric intraocular lens.

Authors:  Antoine Levron; Hussam El Chehab; Emilie Agard; Roman Chudzinski; Jeremy Billant; Corinne Dot
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-01-15       Impact factor: 3.117

2.  Comparing refractive outcomes of a standard industry toric IOL calculator using anterior corneal astigmatism and total corneal refractive power.

Authors:  C Kern; L El Kaissi; K Kortuem; M Shajari; E Vounotrypidis; A Langenbucher; S Priglinger; W J Mayer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-12-20       Impact factor: 3.117

Review 3.  Toric intraocular lenses: Evidence-based use.

Authors:  Michael Goggin
Journal:  Clin Exp Ophthalmol       Date:  2022-05-29       Impact factor: 4.383