Literature DB >> 29115696

Joule heating induced stream broadening in free-flow zone electrophoresis.

Debashis Dutta1.   

Abstract

The use of an electric field in free-flow zone electrophoresis (FFZE) automatically leads to Joule heating yielding a higher temperature at the center of the separation chamber relative to that around the channel walls. For small amounts of heat generated, this thermal effect introduces a variation in the equilibrium position of the analyte molecules due to the dependence of liquid viscosity and analyte diffusivity on temperature leading to a modification in the position of the analyte stream as well as the zone width. In this article, an analytic theory is presented to quantitate such effects of Joule heating on FFZE assays in the limit of small temperature differentials across the channel gap yielding a closed form expression for the stream position and zone variance under equilibrium conditions. A method-of-moments approach is employed to develop this analytic theory, which is further validated with numerical solutions of the governing equations. Interestingly, the noted analyses predict that Joule heating can drift the location of the analyte stream either way of its equilibrium position realized in the absence of any temperature rise in the system, and also tends to reduce zone dispersion. The extent of these modifications, however, is governed by the electric field induced temperature rise and three Péclet numbers evaluated based on the axial pressure-driven flow, transverse electroosmotic and electrophoretic solute velocities in the separation chamber. Monte Carlo simulations of the FFZE system further establish a time and a length scale over which the results from the analytic theory are valid.
© 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Band broadening; Free-flow zone electrophoresis; Joule heating; Mathematical modeling; Method-of-moments

Mesh:

Substances:

Year:  2017        PMID: 29115696      PMCID: PMC5929496          DOI: 10.1002/elps.201700307

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  13 in total

1.  Electroosmotic flow with Joule heating effects.

Authors:  Xiangchun Xuan; Bo Xu; David Sinton; Dongqing Li
Journal:  Lab Chip       Date:  2004-02-23       Impact factor: 6.799

2.  Effect of Channel Sidewalls on Joule Heating Induced Sample Dispersion in Rectangular Ducts.

Authors:  Debashis Dutta
Journal:  Int J Heat Mass Transf       Date:  2016-02-01       Impact factor: 5.584

3.  Optimizing band width and resolution in micro-free flow electrophoresis.

Authors:  Bryan R Fonslow; Michael T Bowser
Journal:  Anal Chem       Date:  2006-12-15       Impact factor: 6.986

Review 4.  Continuous free-flow electrophoresis.

Authors:  L Krivánková; P Bocek
Journal:  Electrophoresis       Date:  1998-06       Impact factor: 3.535

5.  An analytic description of electrodynamic dispersion in free-flow zone electrophoresis.

Authors:  Debashis Dutta
Journal:  J Chromatogr A       Date:  2015-06-01       Impact factor: 4.759

Review 6.  Continuous downstream processing for high value biological products: A Review.

Authors:  Andrew L Zydney
Journal:  Biotechnol Bioeng       Date:  2015-08-27       Impact factor: 4.530

7.  Broadening of analyte streams due to a transverse pressure gradient in free-flow isoelectric focusing.

Authors:  Debashis Dutta
Journal:  J Chromatogr A       Date:  2017-01-03       Impact factor: 4.759

Review 8.  Microfluidic Devices for Circulating Tumor Cells Isolation and Subsequent Analysis.

Authors:  Avid Khamenehfar; Paul C H Li
Journal:  Curr Pharm Biotechnol       Date:  2016       Impact factor: 2.837

Review 9.  Miniaturization of aqueous two-phase extraction for biological applications: From micro-tubes to microchannels.

Authors:  Ruben R G Soares; Daniel F C Silva; Pedro Fernandes; Ana M Azevedo; Virginia Chu; João P Conde; M Raquel Aires-Barros
Journal:  Biotechnol J       Date:  2016-09-14       Impact factor: 4.677

Review 10.  Micro free-flow electrophoresis: theory and applications.

Authors:  Ryan T Turgeon; Michael T Bowser
Journal:  Anal Bioanal Chem       Date:  2009-03-17       Impact factor: 4.142

View more
  3 in total

1.  Stream broadening due to fluid shear across the wider transverse dimension of a free-flow zone electrophoresis channel.

Authors:  Debashis Dutta
Journal:  Phys Fluids (1994)       Date:  2019-07-24       Impact factor: 3.521

Review 2.  Challenging Bioanalyses with Capillary Electrophoresis.

Authors:  Courtney J Kristoff; Lloyd Bwanali; Lindsay M Veltri; Gayatri P Gautam; Patrick K Rutto; Ebenezer O Newton; Lisa A Holland
Journal:  Anal Chem       Date:  2019-12-02       Impact factor: 6.986

3.  Structure and effective charge characterization of proteins by a mobility capillary electrophoresis based method.

Authors:  Wenjing Zhang; Haimei Wu; Rongkai Zhang; Xiang Fang; Wei Xu
Journal:  Chem Sci       Date:  2019-07-03       Impact factor: 9.825

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.