Literature DB >> 29114928

A new substitute for formalin: Application to embalming cadavers.

Yoshinori Haizuka1, Miki Nagase1, Satoshi Takashino1,2, Yasushi Kobayashi3, Yoshihisa Fujikura4, George Matsumura1.   

Abstract

The development of formalin-free fixatives is an urgent issue in gross anatomy because of the health hazard and the tissue-hardening actions of formalin. We recently identified the fixative, antimicrobial, and preservative effects of N-vinyl-2-pyrrolidone (NVP), a precursor of the water-soluble macromolecular polymer polyvinylpyrrolidone, in animal experiments. The aim of the present study is to investigate whether NVP solution can be used as an alternative to formalin in human cadaveric dissection. Twelve donated cadavers were infused with NVP via the femoral and common carotid arteries using a peristaltic pump. Experienced teaching staff members in our department dissected the cadavers and examined their macroanatomical properties. The NVP-embalmed corpses showed no sign of decomposition or fungal growth. The bodies remained soft and flexible. Notably, the shoulder, elbow, wrist, phalangeal, hip, knee, cervical spine, and temporomandibular joints were highly mobile, almost equivalent to those of living individuals. The range of motion of most joints was greater in the NVP-fixed than formalin-fixed cadavers. Under the dermis, the subcutaneous fat was markedly reduced and the connective tissues were transparent, so the ligaments, cutaneous nerves, and veins were easily discernible. The abdominal wall and the visceral organs remained pliable and elastic, resembling those of fresh cadavers. The lungs, liver, and gastrointestinal tract were moveable in the thoracic and abdominal cavities and were readily isolated. NVP can be used successfully as a fixative and preservative solution for human cadavers; furthermore, NVP-embalmed bodies could be valuable for learning clinical skills and for training, and for developing innovative medical devices. Clin. Anat. 31:90-98, 2018.
© 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  anatomy; clinical skills; formalin; joint range of motion; pyrrolidone

Mesh:

Substances:

Year:  2017        PMID: 29114928     DOI: 10.1002/ca.23011

Source DB:  PubMed          Journal:  Clin Anat        ISSN: 0897-3806            Impact factor:   2.414


  8 in total

1.  Current state of surgical training using cadavers in Japan compared with Western countries.

Authors:  Eiji Kobayashi; Jiro Nudeshima
Journal:  Surg Today       Date:  2018-05-16       Impact factor: 2.549

Review 2.  Formalin-free soft embalming of human cadavers using N-vinyl-2-pyrrolidone: perspectives for cadaver surgical training and medical device development.

Authors:  Miki Nagase; Takashi Nagase; Joho Tokumine; Koichiro Saito; Eiji Sunami; Yoshiaki Shiokawa; George Matsumura
Journal:  Anat Sci Int       Date:  2022-04-22       Impact factor: 1.741

3.  A Novel Cadaveric Embalming Technique for Enhancing Visualisation of Human Anatomy.

Authors:  Brian Thompson; Emily Green; Kayleigh Scotcher; Iain D Keenan
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 2.622

Review 4.  The risk of Creutzfeldt-Jakob disease infection in cadaveric surgical training.

Authors:  Keiko Ogami-Takamura; Kazunobu Saiki; Daisuke Endo; Kiyohito Murai; Toshiyuki Tsurumoto
Journal:  Anat Sci Int       Date:  2022-03-21       Impact factor: 1.741

5.  Excised human larynx in N-vinyl-2-pyrrolidone-embalmed cadavers can produce voiced sound by pliable vocal fold vibration.

Authors:  Makoto Miyamoto; Miki Nagase; Itaru Watanabe; Hideki Nakagawa; Kanae Karita; Domingos Hiroshi Tsuji; Arlindo Neto Montagnoli; George Matsumura; Koichiro Saito
Journal:  Anat Sci Int       Date:  2022-02-03       Impact factor: 1.693

6.  Usefulness of N-vinyl-2-pyrrolidone Embalming for Endoscopic Transnasal Skull Base Approach in Cadaver Dissection.

Authors:  Keisuke Maruyama; Hidenori Yokoi; Miki Nagase; Hiroki Yoshida; Akio Noguchi; George Matsumura; Koichiro Saito; Yoshiaki Shiokawa
Journal:  Neurol Med Chir (Tokyo)       Date:  2019-07-04       Impact factor: 1.742

Review 7.  COVID-19 in the autopsy room-requirements, safety, recommendations and pathological findings.

Authors:  Jacek Baj; Marzanna Ciesielka; Grzegorz Buszewicz; Ryszard Maciejewski; Barbara Budzyńska; Piotr Listos; Grzegorz Teresiński
Journal:  Forensic Sci Med Pathol       Date:  2021-01-04       Impact factor: 2.007

8.  Novel high-quality and reality biomaterial as a kidney surgery simulation model.

Authors:  Taro Kubo; Tatsuya Takayama; Akira Fujisaki; Shigeru Nakamura; Takumi Teratani; Naohiro Sata; Joji Kitayama; Hideo Nakai; Daiki Iwami; Tetsuya Fujimura
Journal:  PLoS One       Date:  2022-02-17       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.