Literature DB >> 29114650

Electrochemical reactive oxygen species detection by cytochrome c immobilized with vertically aligned and electrochemically reduced graphene oxide on a glassy carbon electrode.

Dinakaran Thirumalai1, Vijayaraj Kathiresan, Jaewon Lee, Sung-Ho Jin, Seung-Cheol Chang.   

Abstract

A new amperometric biosensor for hydrogen peroxide (H2O2) and superoxide anion (SO) has been developed. The biosensor developed uses cytochrome c (Cyt c) modified glassy carbon electrodes coupled with electrochemically reduced graphene oxide (ErGO). To immobilize Cyt c, the "one step" electrochemical deposition of vertically aligned and ErGO (VAErGO) has been performed by using a pulse reverse technique, thus resulting in a very simple and efficient system. The well-established vertical alignment of ErGO was confirmed by atomic force microscopy and the electrochemical characteristics of the biosensor were investigated by cyclic voltammetric, electrochemical impedance spectroscopy and amperometric techniques. The surface coverage (Γ) of immobilized Cyt c was effectively increased by the vertical alignment of ErGO and found to be 1.03 × 10-10 mol cm-2. The direct electron transfer property of Cyt c was also improved by VAErGO and the heterogeneous electron transfer rate constant (ket) was estimated to be 6.40 s-1. To detect H2O2 and SO, amperometric measurements were carried out at different operating potentials (0.0 V vs. Ag/AgCl for H2O2 and +0.2 V for SO). The sensitivity and detection limit for H2O2 were found to be 46.3 μA mM-1 cm-2 and 2.3 μM, and for SO were found to be 32.1 μM nA-1 cm-2 and 6.84 nM s-1, respectively. Additionally, the designed biosensor exhibited strong anti-interference ability and satisfactory reproducibility.

Entities:  

Year:  2017        PMID: 29114650     DOI: 10.1039/c7an01387f

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  3 in total

Review 1.  Detection Technologies for Reactive Oxygen Species: Fluorescence and Electrochemical Methods and Their Applications.

Authors:  Surachet Duanghathaipornsuk; Eveline J Farrell; Ana C Alba-Rubio; Piotr Zelenay; Dong-Shik Kim
Journal:  Biosensors (Basel)       Date:  2021-01-24

2.  Real-time monitoring of cellular oxidative stress during aerosol sampling: a proof of concept study.

Authors:  Lynn E Secondo; Vitaliy Avrutin; Umit Ozgur; Erdem Topsakal; Nastassja A Lewinski
Journal:  Drug Chem Toxicol       Date:  2020-06-12       Impact factor: 3.356

3.  Novel method for rapid toxicity screening of magnetic nanoparticles.

Authors:  A Erofeev; P Gorelkin; A Garanina; A Alova; M Efremova; N Vorobyeva; C Edwards; Y Korchev; A Majouga
Journal:  Sci Rep       Date:  2018-05-10       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.