| Literature DB >> 29114577 |
Yu D Ivanov1, A F Kozlov1, К А Malsagova1, Т О Pleshakova1, S G Vesnin2, V Yu Tatur3, N D Ivanova4, V S Ziborov5.
Abstract
Monitoring of microwave emission from aqueous solution of horseradish peroxidase (HRP) in the process of the enzyme functioning was carried out. For the monitoring, a system containing HRP, luminol and Н2О2 was employed. Microwave emission measurements were carried out in the 3.4-4.2 GHz frequency range using the active and passive modes (active-mode and passive-mode measurements). In the active mode, excitation of the solution in the pulsed electromagnetic field was accomplished. In the passive mode, no excitation was induced. It appears that the passive-mode measurements taken in the course of the peroxidase reaction in the enzyme system have shown a 0.5 °С increase of the microwave signal. Upon the active-mode measurements, taken in the same reaction conditions, the forced excitation of the solution has also led to the increase (by 2 °С) of the level of the microwave signal - i.e. to its 4-fold enhancement compared to the signal obtained in passive-mode measurements.Entities:
Keywords: Enzyme system; Horseradish peroxidase; Microwave emission
Year: 2016 PMID: 29114577 PMCID: PMC5627140 DOI: 10.1016/j.bbrep.2016.05.003
Source DB: PubMed Journal: Biochem Biophys Rep ISSN: 2405-5808
Fig. 1Experimental scheme for the active-mode measurements of microwave emission from HRP solution. (1) – freshly cleaved HOPG; (2) – mica sheet; (3) – PTFE film; (4) – PTFE cell; (5) – HRP solution; (6) – Pt electrode; (7) – flagpole antenna; (8) - radiothermometer; (9) – pulse generator.
Fig. 2Results of passive-mode measurements of microwave emission. (А) – Results of control experiments according to the schemes of enzyme system components addition (1) and (2) (see the “Materials and Methods” section); (В) – Results of control experiments according to the schemes of enzyme system components addition (3) (see the “Materials and Methods” section); (С) – Result of measurement in reconstructed HRP-based system. Experimental conditions: - components concentration: 1 µM HRP; addition of 1 mM luminol; addition of 0.1 mM H2O2; - temperature of measurements 24 °С;- absence of pulsed electric field; Arrows indicate the time points of addition of aliquots of enzyme system components solution or water into the reaction solution.
Fig. 3Results of active-mode measurements of microwave emission. (А) – Results of control experiments according to the schemes of enzyme system components addition (1) and (2) (see the “Materials and Methods” section); (В) – Results of control experiments according to the schemes of enzyme system components addition (3) (см (see “Materials and Methods” section); (С) – Results of measurement in the reconstructed HRP-based system. Experimental conditions: - components concentration: 1 µM HRP; addition of 1 mM luminol; addition of 0.1 mM H2O2; - temperature of measurements 24 °С; - electric field pulse parameters: period 20 μs, pulse width 10 μs, amplitude 10 V. Arrows indicate the time points of addition of aliquots of enzyme system components solution or of water in the reaction solution.