Biomechanical investigation of four different fixation techniques in sacrum Denis type II fracture with low bone mineral density.

Yves P Acklin1, Ivan Zderic1, Robert G Richards1, Paul Schmitz2, Boyko Gueorguiev1, Stephan Grechenig2.   

Abstract

With increasing life expectancy, fragility fractures of the pelvic ring are seen more frequently. Although their osteosynthesis can be very challenging, specific biomechanical studies for investigation of the fixation stability are still lacking. The aim of this study was to biomechanically evaluate four different fixation methods for sacrum Denis type II fractures in osteoporotic bone. Unstable Denis type II vertical sacrum fractures were created in 16 human pelves. Their osteosynthesis was performed with one sacro-iliac screw, posterior sacral plating, triangular fixation, or spino-pelvic fixation. For that purpose, each pelvis was randomly assigned to two paired groups for treatment with either SI-screw/posterior sacral plating or triangular fixation/spino-pelvic fixation. Each hemi-pelvis was cyclically tested under progressively increasing axial compression. Relative interfragmentary movements were investigated via optical motion tracking analysis. Axial stiffness of triangular fixation was significantly higher versus posterior sacral plating and spino-pelvic fixation (p ≤ 0.022), but not significantly different in comparison to SI-screw fixation (p = 0.337). Cycles to 2, 3, 5, and 8 mm fracture displacement, as well as to 3°, 5°, and 8° gap angle at the fracture site were significantly higher for triangular fixation compared to all other groups (p ≤ 0.041). Main failure mode for all osteosynthesis techniques was screw cutting through the bone, leading loss of fixation stability. From a biomechanical point of view, triangular fixation in sacrum Denis type II fractures demonstrated less interfragmentary movements and should be considered in unstable fragility fractures of the sacrum.
© 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1624-1629, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  fragility sacrum fracture; posterior sacral plating; triangular fixation

Mesh:

Year:  2017        PMID: 29106756     DOI: 10.1002/jor.23798

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  2 in total

1.  Posterior INFIX for Treating Unilateral Unstable Sacral Fractures.

Authors:  Haotian Qi; Xin Geng; Xiaokun Yu; Wenhuan Chen; Jian Jia; Wei Tian
Journal:  Orthop Surg       Date:  2022-03-27       Impact factor: 2.071

2.  Does Cement Augmentation of the Sacroiliac Screw Lead to Superior Biomechanical Results for Fixation of the Posterior Pelvic Ring? A Biomechanical Study.

Authors:  Moritz F Lodde; J Christoph Katthagen; Clemens O Schopper; Ivan Zderic; R Geoff Richards; Boyko Gueorguiev; Michael J Raschke; René Hartensuer
Journal:  Medicina (Kaunas)       Date:  2021-12-16       Impact factor: 2.430

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.