| Literature DB >> 29104597 |
Negin Nasoohi1, Maryam Hoorizad1, Seyedeh Farnaz Tabatabaei2.
Abstract
OBJECTIVES: This study aimed to assess the effect of wet and dry finishing and polishing on microhardness and roughness of microhybrid and nanohybrid composites.Entities:
Keywords: Composite Resins; Dental Polishing; Hardness
Year: 2017 PMID: 29104597 PMCID: PMC5662511
Source DB: PubMed Journal: J Dent (Tehran) ISSN: 1735-2150
Composite resins used in the study according to the information provided by the manufacturers
| Aelite Aesthetic Enamel (BISCO, Schaumburg, USA) | Nanohybrid composite | Ethoxylated Bis-GMA, TEGDMA | 0.5–2μm | Glass filler, amorphous silica | 53 | 73 | A2 | 1600004511 |
| Aelite All Purpose Body (BISCO, Schaumburg, USA) | Microhybrid composite | Ethoxylated Bis-GMA, TEGDMA | 0.04–0.7μm | Glass filler, amorphous silica | 55 | 76 | A2 | 1600004474 |
| Grandio (Voco, Cuxhaven, Germany) | Nanohybrid composite | Bis-GMA, dimethacrylate, UDMA, TEGDMA | 1μm, 20–50nm | Ba-Al-borosilicate glass filler, nanofiller (SiO2) | 71.4 | 87 | A2 | 1536078 |
| Polofil supra (Voco, Cuxhaven, Germany) | Microhybrid composite | Bis-GMA, TEGDMA, UDMA | 0.04–5μm | Glass filler, silica | 60 | 76.5 | A2 | 1408140 |
Mean surface roughness (Ra, μm) and Vickers microhardness (kg/mm2) values and standard deviations for the tested materials and polishing procedures
| Aelite Aesthetic Enamel | 0.02±0.01Aa | 0.11± 0.01Ab | 0.15± 0.01Ac | 61.00± 2.06Aa | 75.68± 2.09Ab | 94.37± 2.99Ac |
| Aelite All Purpose Body | 0.04±0.01Aa | 0.13± 0.02Ab | 0.16± 0.01Ac | 63.97± 2.54Aa | 78.20± 2.23Ab | 96.78± 2.10Ac |
| Grandio | 0.05±0.01Aa | 0.32± 0.02Bb | 0.43± 0.02Bc | 115.09±6.56Ba | 163.75± 2.86Bb | 199.92± 4.47Bc |
| Polofil Supra | 0.03±0.01Aa | 0.13±0.01Ab | 0.17±0.01Ac | 61.23± 1.92Aa | 76.15± 2.33Ab | 96.20± 3.75Ac |
C: Control, W: Wet finishing/polishing, D: Dry finishing/polishing
Means followed by different lowercase letters show statistically significant differences between them, as compared in rows.
Means followed by the same uppercase letters do not show statistically significant differences between them, as compared in columns.