Literature DB >> 29102856

Validity and reliability of an iPhone App to assess time, velocity and leg power during a sit-to-stand functional performance test.

Juan Diego Ruiz-Cárdenas1, Juan José Rodríguez-Juan2, Rowan R Smart3, Jennifer M Jakobi3, Gareth R Jones3.   

Abstract

The purposes of this study were: (i) Analyze the concurrent validity and reliability of an iPhone App for measuring time, velocity and power during a single sit-to-stand (STS) test compared with measurements recorded from a force plate; and (ii) Evaluate the relationship between the iPhone App measures with age and functional performance. Forty-eight healthy individuals (age range: 26-81 years) were recruited. All participants completed a STS test on a force plate with the movement recorded on an iPhone 6 at 240 frames-per-second. Functional ability was also measured using isometric handgrip strength and self-paced walking time tests. Intraclass correlation coefficients (ICC), Pearson's correlation coefficient, Cronbach's alpha (α) and Bland-Altman plots with 95% confidence intervals (CI) were used to test validity and reliability between instruments. The results showed a good agreement between all STS measurement variables; time (ICC=0.864, 95%CI=0.77-0.92; α=0.926), velocity (ICC=0.912, 95%CI=0.85-0.95; α=0.953) and power (ICC=0.846, 95%CI=0.74-0.91; α=0.917) with no systematic bias between instruments for any variable analyzed. STS time, velocity and power derived from the iPhone App show moderate to strong associations with age (|r|=0.63-0.83) and handgrip strength (|r|=0.4-0.64) but not the walking test. The results of this study identify that this iPhone App is reliable for measuring STS and the derived values of time, velocity and power shows strong associations with age and handgrip strength.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Age; Leg strength assessment; Physical performance

Mesh:

Year:  2017        PMID: 29102856     DOI: 10.1016/j.gaitpost.2017.10.029

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  6 in total

1.  Effects of supervised high-intensity hardstyle kettlebell training on grip strength and health-related physical fitness in insufficiently active older adults: the BELL pragmatic controlled trial.

Authors:  Neil J Meigh; Justin W L Keogh; Ben Schram; Wayne Hing; Evelyne N Rathbone
Journal:  BMC Geriatr       Date:  2022-04-22       Impact factor: 4.070

2.  A body-fixed-sensor-based analysis of stair ascent and sit-to-stand to detect age-related differences in leg-extensor power.

Authors:  Evelien Van Roie; Stijn Van Driessche; Bas Huijben; Remco Baggen; Rob C van Lummel; Christophe Delecluse
Journal:  PLoS One       Date:  2019-01-17       Impact factor: 3.240

3.  Test-Retest Reliability of Home-Based Fitness Assessments Using a Mobile App (R Plus Health) in Healthy Adults: Prospective Quantitative Study.

Authors:  I-I Lin; You-Lin Chen; Li-Ling Chuang
Journal:  JMIR Form Res       Date:  2021-12-08

4.  Validity of an iPhone App to Detect Prefrailty and Sarcopenia Syndromes in Community-Dwelling Older Adults: The Protocol for a Diagnostic Accuracy Study.

Authors:  Alessio Montemurro; Juan D Ruiz-Cárdenas; María Del Mar Martínez-García; Juan J Rodríguez-Juan
Journal:  Sensors (Basel)       Date:  2022-08-11       Impact factor: 3.847

5.  Sit-To-Stand Movement Evaluated Using an Inertial Measurement Unit Embedded in Smart Glasses-A Validation Study.

Authors:  Justine Hellec; Frédéric Chorin; Andrea Castagnetti; Serge S Colson
Journal:  Sensors (Basel)       Date:  2020-09-04       Impact factor: 3.576

6.  An Experimental Study on the Validity and Reliability of a Smartphone Application to Acquire Temporal Variables during the Single Sit-to-Stand Test with Older Adults.

Authors:  Diogo Luís Marques; Henrique Pereira Neiva; Ivan Miguel Pires; Eftim Zdravevski; Martin Mihajlov; Nuno M Garcia; Juan Diego Ruiz-Cárdenas; Daniel Almeida Marinho; Mário Cardoso Marques
Journal:  Sensors (Basel)       Date:  2021-03-15       Impact factor: 3.576