Literature DB >> 29102855

Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests.

Francesc Medina-Mirapeix1, Iván Vivo-Fernández1, Juan López-Cañizares1, José A García-Vidal1, Josep Carles Benítez-Martínez2, María Elena Del Baño-Aledo3.   

Abstract

The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. Pearson coefficient was calculated to assess the correlation between 5STS, time up to go test (TUG) and four meters gait speed (4MGS). ICC for inter-observer and test-retest reliability of the 5STS were 0.998 (95% confidence interval [CI], 0.995-0.999) and 0.982 (95% CI, 0.959-0.992). Bland-Altman plot inter-observer showed limits between -0.82 and 1.06 with a mean of 0.11 and no heteroscedasticity within the data. Bland-Altman plot for test-retest showed the limits between 1.76 and 4.16, a mean of 1.20 and heteroscedasticity within the data. Pearson correlation coefficient revealed significant correlation between 5STS and TUG (r=0.7, p<0.001) and 4MGS (r=-0.583, p=0.003). This study demonstrates excellent inter-observer and test-retest reliability when it is used in people with TKR, and also significant correlation with other functional mobility tests. These findings support the use of 5STS as outcome measure in TKR population.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Five-repetition sit-to-stand test; Reliability; Total knee replacement

Mesh:

Year:  2017        PMID: 29102855     DOI: 10.1016/j.gaitpost.2017.10.028

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  3 in total

1.  Five-Repetition Sit-to-Stand Test Performance in Healthy Individuals: Reference Values and Predictors From 2 Prospective Cohorts.

Authors:  Anita M Klukowska; Victor E Staartjes; W Peter Vandertop; Marc L Schröder
Journal:  Neurospine       Date:  2021-12-31

2.  Test-Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adults.

Authors:  Daniel Jerez-Mayorga; Álvaro Huerta-Ojeda; Luis Javier Chirosa-Ríos; Francisco Guede-Rojas; Iris Paola Guzmán-Guzmán; Leonardo Intelangelo; Claudia Miranda-Fuentes; Pedro Delgado-Floody
Journal:  Int J Environ Res Public Health       Date:  2021-06-25       Impact factor: 3.390

3.  Association between Kinesiophobia and Knee Pain Intensity, Joint Position Sense, and Functional Performance in Individuals with Bilateral Knee Osteoarthritis.

Authors:  Mastour Saeed Alshahrani; Ravi Shankar Reddy; Jaya Shanker Tedla; Faisal Asiri; Adel Alshahrani
Journal:  Healthcare (Basel)       Date:  2022-01-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.