Literature DB >> 29100914

Powder flow analysis: A simple method to indicate the ideal amount of lactose fines in dry powder inhaler formulations.

Mats Hertel1, Eugen Schwarz2, Mirjam Kobler2, Sabine Hauptstein2, Hartwig Steckel3, Regina Scherließ4.   

Abstract

Many efforts have been made in the past to understand the function of lactose fines which are given as a ternary component to carrier-based dry powder inhaler formulations. It is undisputed that fines can significantly improve the performance of such formulations, but choosing the right amount of fines is a crucial point, because too high concentrations can have negative effects on the dispersion performance. The aim of this study was to indicate the optimal concentration of fines with a simple test method. For this purpose, mixtures with salbutamol sulfate and two different lactose carriers were prepared with a high shear mixer, measured with a FT4 powder rheometer and tested for fine particle delivery with two different inhaler devices. A correlation between the fluidization energy, measured with the aeration test set up, and the fine particle fractions (FPF) could be proven. This also applied for the aeration ratio, as well as the permeability of the powder samples. In addition, drug-free mixtures hardly differed in their rheological properties from mixtures containing the active pharmaceutical ingredient (API), which indicates that the method could be suitable for cost-saving screening trials. Furthermore, important aspects that explain the function of fines, such as the saturation of active sites, the formation of agglomerates and an increase in fluidization energy, could be shown in this study.
Copyright © 2017. Published by Elsevier B.V.

Entities:  

Keywords:  Alpha-lactose monohydrate (PubChem CID: 04938); Fines; High shear mixing; Powder flow analysis; Salbutamol sulfate (PubChem CID: 39859); Ternary mixtures

Mesh:

Substances:

Year:  2017        PMID: 29100914     DOI: 10.1016/j.ijpharm.2017.10.052

Source DB:  PubMed          Journal:  Int J Pharm        ISSN: 0378-5173            Impact factor:   5.875


  2 in total

1.  Micro-Dosing of Fine Cohesive Powders Actuated by Pulse Inertia Force.

Authors:  Hongcheng Wang; Ting Zhang; Miaomiao Zhao; Rangrang Chen; Liqun Wu
Journal:  Micromachines (Basel)       Date:  2018-02-07       Impact factor: 2.891

2.  Spray-Congealing and Wet-Sieving as Alternative Processes for Engineering of Inhalation Carrier Particles: Comparison of Surface Properties, Blending and In Vitro Performance.

Authors:  Joana T Pinto; Sarah Zellnitz; Tomaso Guidi; Francesca Schiaretti; Hartmuth Schroettner; Amrit Paudel
Journal:  Pharm Res       Date:  2021-06-10       Impact factor: 4.200

  2 in total