Literature DB >> 29093282

Peri-implant strain around mesially inclined two-implant-retained mandibular overdentures with Locator attachments.

Moustafa A Elsyad1, Salem M Eltowery1, Ashraf A Gebreel1.   

Abstract

This study aimed to evaluate the peri-implant strain around mesially inclined implants used to retain mandibular overdentures with Locator resilient attachments. Four mandibular edentulous acrylic resin models received two implants in the canine areas with 0°, 5°, 10°, and 20° mesial inclinations. Overdentures were connected to the implants using Locator attachments. Pink nylon inserts (light retention) were used for all implant inclinations, and red inserts were used for 20° inclination (20°red). Four strain gages were bonded on the mesial (M), distal (D), buccal (B), and lingual (L) surfaces of each implant. Peri-implant strains were measured during bilateral and unilateral loading. The 20° inclination showed the highest strain, followed by 10° and 5°, and both 0° and 20°red presented with the lowest strain. Site D was associated with the highest strain, followed by M, B, and L, which showed the lowest strain values. Unilateral loading and the loading side presented with significantly higher strain values than bilateral loading and the nonloading side, respectively. Hence, in this study, strains around the two-implant-retained overdentures with Locator attachments increased with increases in mesial implant angulation, except when red male inserts were used.

Entities:  

Keywords:  Locator; implant inclination; overdentures; stresses

Mesh:

Substances:

Year:  2017        PMID: 29093282     DOI: 10.2334/josnusd.16-0626

Source DB:  PubMed          Journal:  J Oral Sci        ISSN: 1343-4934            Impact factor:   1.556


  2 in total

1.  Geometric Reproducibility of Three-Dimensional Oral Implant Planning Based on Magnetic Resonance Imaging and Cone-Beam Computed Tomography.

Authors:  Franz Sebastian Schwindling; Sophia Boehm; Christopher Herpel; Dorothea Kronsteiner; Lorenz Vogel; Alexander Juerchott; Sabine Heiland; Martin Bendszus; Peter Rammelsberg; Tim Hilgenfeld
Journal:  J Clin Med       Date:  2021-11-26       Impact factor: 4.241

2.  Comparison of tensile bond strength of ball attachments made of different materials to root canal dentin after chewing simulation.

Authors:  Ahmed Mostafa Abdelfattah Mohamed; Mahmoud El-Moutassem Bellah El Homossany; Sarah Mohamed Abdelmoniem; Tariq Yehia Abdelrahman
Journal:  BMC Oral Health       Date:  2022-06-24       Impact factor: 3.747