Invalidation of the resting electrocardiogram obtained via exercise electrode sites as a standard 12-lead recording.

D C Sevilla1, M L Dohrmann, C A Somelofski, R P Wawrzynski, N B Wagner, G S Wagner.   

Abstract

The difficulty in interpreting the standard 12-lead electrocardiogram (ECG) due to the interference from muscle potentials produced by arm and leg motion makes it unsuitable during the exercise treadmill test. Likewise, the exercise lead placement ECG cannot substitute for the standard ECG due to significant errors in the former's diagnostic interpretation. This study compares the ECGs recorded via standard and exercise sites regarding frontal and horizontal plane axes, diagnosis and location of myocardial infarction and estimation of infarct size using the complete 54-criteria and 32-point Selvester QRS scoring system. The altered limb lead locations on the exercise ECG caused the QRS vectors to artifactually appear to be directed more inferiorly, posteriorly and rightward, producing a marked rightward mean frontal plane axis shift of +48 degrees (p less than 0.00001). No false positive or false negative anterior infarct was seen on the exercise lead placement ECG, whereas inferior and posterior infarcts were lost in 69% and 31% of patients, respectively. A false lateral infarct was seen in 19% of patients. Estimation of infarct size differed between the 2 ECG sets, with 11 patients increasing their infarct size by 3 to 9% and 14 others decreasing it by 3 to 15% on the exercise lead placement ECG. This study demonstrates that use of body torso positions for limb leads results in substantial QRS waveform variations that disqualify the exercise lead placement ECG as a "standard" recording. Such ECGs should therefore be labeled as "torso positioned" or "nonstandard" to prevent misuse for clinical and investigative purposes.

Entities:  

Mesh:

Year:  1989        PMID: 2909158     DOI: 10.1016/0002-9149(89)91072-2

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  10 in total

1.  Modified electrode placement must be recorded when performing 12-lead electrocardiograms.

Authors:  N I Jowett; A M Turner; A Cole; P A Jones
Journal:  Postgrad Med J       Date:  2005-02       Impact factor: 2.401

Review 2.  Phosphodiesterase inhibitors: new opportunities for the treatment of asthma.

Authors:  T J Torphy; B J Undem
Journal:  Thorax       Date:  1991-07       Impact factor: 9.139

Review 3.  Technical mistakes during the acquisition of the electrocardiogram.

Authors:  Javier García-Niebla; Pablo Llontop-García; Juan Ignacio Valle-Racero; Guillem Serra-Autonell; Velislav N Batchvarov; Antonio Bayés de Luna
Journal:  Ann Noninvasive Electrocardiol       Date:  2009-10       Impact factor: 1.468

4.  High-risk electrocardiographic parameters are ubiquitous in patients with ischemic cardiomyopathy.

Authors:  Mary G Carey; Salah S Al-Zaiti; John M Canty; James A Fallavollita
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-07       Impact factor: 1.468

Review 5.  Main artifacts in electrocardiography.

Authors:  Andrés Ricardo Pérez-Riera; Raimundo Barbosa-Barros; Rodrigo Daminello-Raimundo; Luiz Carlos de Abreu
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-09-20       Impact factor: 1.468

6.  Performance and limitations of automated ECG interpretation statements in patients with suspected acute coronary syndrome.

Authors:  Ziad Faramand; Stephanie Helman; Abdullah Ahmad; Christian Martin-Gill; Clifton Callaway; Samir Saba; Richard E Gregg; John Wang; Salah Al-Zaiti
Journal:  J Electrocardiol       Date:  2021-08-18       Impact factor: 1.438

7.  A new electrode placement method for obtaining 12-lead ECGs.

Authors:  Gabriel M Khan
Journal:  Open Heart       Date:  2015-06-09

8.  True unipolar ECG machine for Wilson Central Terminal measurements.

Authors:  Gaetano D Gargiulo
Journal:  Biomed Res Int       Date:  2015-10-01       Impact factor: 3.411

9.  Normal limits of ECG measurements related to atrial activity using a modified limb lead system.

Authors:  Jayaraman Sivaraman; Gandhi Uma; Sangareddi Venkatesan; Mangalanathan Umapathy; Vella Elumalai Dhandapani
Journal:  Anatol J Cardiol       Date:  2014-02-26       Impact factor: 1.596

10.  Modified limb lead ECG system effects on electrocardiographic wave amplitudes and frontal plane axis in sinus rhythm subjects.

Authors:  Sivaraman Jayaraman; Venkatesan Sangareddi; R Periyasamy; Justin Joseph; Ravi Marimuthu Shanmugam
Journal:  Anatol J Cardiol       Date:  2016-06-29       Impact factor: 1.596

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.