The validity and inter-device variability of the Apple Watch™ for measuring maximal heart rate.

Grant Abt1, James Bray1, Amanda Clare Benson2.   

Abstract

Maximal heart rate (HRmax) is a fundamental measure used in exercise prescription. The Apple Watch™ measures heart rate yet the validity and inter-device variability of the device for measuring HRmax are unknown. Fifteen participants completed a maximal oxygen uptake test while wearing an Apple Watch™ on each wrist. Criterion HRmax was measured using a Polar T31™ chest strap. There were good to very good correlations between the watches and criterion (left: r = 0.87 [90%CI: 0.67 to 0.95]; right: r = 0.98 [90%CI: 0.94 to 0.99]). Standardised mean bias for the left and right watches compared to the criterion were 0.14 (90%CI: -0.12 to 0.39; trivial) and 0.04 (90%CI: -0.07 to 0.15; trivial). Standardised typical error of the estimate for the left and right watches compared to the criterion were 0.51 (90%CI: 0.38 to 0.80; moderate) and 0.22 (90%CI: 0.16 to 0.34; small). Inter-device standardised typical error was 0.46 (90%CI: 0.36 to 0.68; moderate), ICC = 0.84 (90%CI: 0.65 to 0.93). The Apple Watch™ has good to very good criterion validity for measuring HRmax, with no substantial under- or over-estimation. There were moderate and small prediction errors for the left and right watches. Inter-device variability in HRmax is moderate.

Entities:  

Keywords:  Intensity; reliability; technology; validity

Mesh:

Year:  2017        PMID: 29090987     DOI: 10.1080/02640414.2017.1397282

Source DB:  PubMed          Journal:  J Sports Sci        ISSN: 0264-0414            Impact factor:   3.337


  12 in total

1.  Evaluating commercially available wireless cardiovascular monitors for measuring and transmitting real-time physiological responses in children with autism.

Authors:  Heather J Nuske; Matthew S Goodwin; Yelena Kushleyeva; Daniel Forsyth; Jeffrey W Pennington; Aaron J Masino; Emma Finkel; Anushua Bhattacharya; Jessica Tan; Hungtzu Tai; Zabryna Atkinson-Diaz; Christopher P Bonafide; John D Herrington
Journal:  Autism Res       Date:  2021-11-06       Impact factor: 4.633

2.  Recommendations for determining the validity of consumer wearable heart rate devices: expert statement and checklist of the INTERLIVE Network.

Authors:  Jan M Mühlen; Julie Stang; Esben Lykke Skovgaard; Pedro B Judice; Pablo Molina-Garcia; William Johnston; Luís B Sardinha; Francisco B Ortega; Brian Caulfield; Wilhelm Bloch; Sulin Cheng; Ulf Ekelund; Jan Christian Brønd; Anders Grøntved; Moritz Schumann
Journal:  Br J Sports Med       Date:  2021-01-04       Impact factor: 13.800

3.  The Polar ® OH1 Optical Heart Rate Sensor is Valid during Moderate-Vigorous Exercise.

Authors:  Matthew M Schubert; Amy Clark; Annie B De La Rosa
Journal:  Sports Med Int Open       Date:  2018-06-17

4.  In-Ear Pulse Rate Measurement: A Valid Alternative to Heart Rate Derived from Electrocardiography?

Authors:  Stefanie Passler; Niklas Müller; Veit Senner
Journal:  Sensors (Basel)       Date:  2019-08-21       Impact factor: 3.576

5.  Measurement of Pulse Wave Signals and Blood Pressure by a Plastic Optical Fiber FBG Sensor.

Authors:  Yuki Haseda; Julien Bonefacino; Hwa-Yaw Tam; Shun Chino; Shouhei Koyama; Hiroaki Ishizawa
Journal:  Sensors (Basel)       Date:  2019-11-21       Impact factor: 3.576

6.  Validation of the Apple Watch for Heart Rate Variability Measurements during Relax and Mental Stress in Healthy Subjects.

Authors:  David Hernando; Surya Roca; Jorge Sancho; Álvaro Alesanco; Raquel Bailón
Journal:  Sensors (Basel)       Date:  2018-08-10       Impact factor: 3.576

7.  Measuring Moderate-Intensity Exercise with the Apple Watch: Validation Study.

Authors:  Grant Abt; James Bray; Amanda Clare Benson
Journal:  JMIR Cardio       Date:  2018-02-28

8.  Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review.

Authors:  Daniel Fuller; Emily Colwell; Jonathan Low; Kassia Orychock; Melissa Ann Tobin; Bo Simango; Richard Buote; Desiree Van Heerden; Hui Luan; Kimberley Cullen; Logan Slade; Nathan G A Taylor
Journal:  JMIR Mhealth Uhealth       Date:  2020-09-08       Impact factor: 4.773

Review 9.  Blood Pressure Sensors: Materials, Fabrication Methods, Performance Evaluations and Future Perspectives.

Authors:  Ahmed Al-Qatatsheh; Yosry Morsi; Ali Zavabeti; Ali Zolfagharian; Nisa Salim; Abbas Z Kouzani; Bobak Mosadegh; Saleh Gharaie
Journal:  Sensors (Basel)       Date:  2020-08-11       Impact factor: 3.576

10.  Validity of the Polar Vantage M watch when measuring heart rate at different exercise intensities.

Authors:  Tricia Shumate; Magdalen Link; James Furness; Kevin Kemp-Smith; Vini Simas; Mike Climstein
Journal:  PeerJ       Date:  2021-02-09       Impact factor: 2.984

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.