Literature DB >> 2908913

Canine bone blood flow estimated with microspheres.

G Li1, J T Bronk, P J Kelly.   

Abstract

Blood flow rate in the periosteal and endosteal cortices of the diaphysis of long bones was determined in eight anesthetized adult dogs using the radioactively labeled microsphere method. The flow rate in endosteal and periosteal cortices is not significantly different unless the endosteal cortex contains cancellous bone from the medullary cavity. The highest flow rate is in the ulna, with 6.50 ml/min/100 g for the endosteal cortex and 5.15 ml/min/100 g for the periosteal cortex. The lowest flow rate is in the femur, with 2.89 ml/min/100 g for the endosteal cortex and 2.29 ml/min/100 g for the periosteal cortex. The results of this study indicate that variation of blood flow does exist between bones of dogs. However, the flow rates of individual bone on the left and right sides in the same dog are not significantly different. This indicates that the data are reproducible and reliable, and differences are not an inaccuracy of the radioactively labeled microsphere method. The results also demonstrate that there are no significant differences in bone blood flow as measured with small numbers (fewer than 400 microspheres per sample) and large numbers (more than 400 microspheres per sample) of microspheres. The adequate number of microspheres in each bone sample is 150-250. Therefore, a dose of 0.5 x 10(6) spheres/kg body weight can be sufficient.

Entities:  

Mesh:

Year:  1989        PMID: 2908913     DOI: 10.1002/jor.1100070109

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  5 in total

1.  Measurement of blood flow to the vertebral bone and disc.

Authors:  S P Hughes; A L Wallace; I D McCarthy; R H Fleming; B C Wyatt
Journal:  Eur Spine J       Date:  1993-08       Impact factor: 3.134

2.  Evaluation of a laser Doppler flowmetry implantable fiber system for determination of threshold thickness for flow detection in bone.

Authors:  E H Schemitsch; M J Kowalski; M F Swiontkowski
Journal:  Calcif Tissue Int       Date:  1994-09       Impact factor: 4.333

3.  Assessment of the relationship between standard probe and implantable fiber measurements of cortical bone blood flow: a canine study.

Authors:  R Jain; N Podworny; G I Anderson; E H Schemitsch
Journal:  Calcif Tissue Int       Date:  1996-07       Impact factor: 4.333

4.  Evaluation of the incorporation of bone grafts used in maxillofacial surgery with [18F]fluoride ion and dynamic positron emission tomography.

Authors:  G Berding; W Burchert; J van den Hoff; C Pytlik; F W Neukam; G J Meyer; K F Gratz; H Hundeshagen
Journal:  Eur J Nucl Med       Date:  1995-10

5.  Regional differences in oxidative metabolism and mitochondrial activity among cortical bone osteocytes.

Authors:  Dorra Frikha-Benayed; Jelena Basta-Pljakic; Robert J Majeska; Mitchell B Schaffler
Journal:  Bone       Date:  2016-05-31       Impact factor: 4.398

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.