Literature DB >> 29089106

Development of Carbotrap B-packed needle trap device for determination of volatile organic compounds in air.

Ali Poormohammadi1, Abdulrahman Bahrami2, Maryam Farhadian3, Farshid Ghorbani Shahna1, Alireza Ghiasvand4.   

Abstract

Carbotrap B as a highly pure surface sorbent with excellent adsorption/desorption properties was packed into a stainless steel needle to develop a new needle trap device (NTD). The performance of the prepared NTD was investigated for sampling, pre-concentration and injection of benzene, toluene, ethyl benzene, o-xylene, and p-xylene (BTEX) into the column of gas chromatography-mass spectrometry (GC-MS) device. Response surface methodology (RSM) with central composite design (CCD) was also employed in two separate consecutive steps to optimize the sampling and device parameters. First, the sampling parameters such as sampling temperature and relative humidity were optimized. Afterwards, the RSM was used for optimizing the desorption parameters including desorption temperature and time. The results indicated that the peak area responses of the analytes of interest decreased with increasing sampling temperature and relative humidity. The optimum values of desorption temperature were in the range 265-273°C, and desorption time were in the range 3.4-3.8min. The limits of detection (LODs) and limits of quantitation (LOQs) of the studied analytes were found over the range of 0.03-0.04ng/mL, and 0.1-0.13ng/mL, respectively. These results demonstrated that the NTD packed with Carbotrap B offers a high sensitive procedure for sampling and analysis of BTEX in concentration range of 0.03-25ng/mL in air.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Air; Carbotrap B; Needle trap device; Response surface methodology; Volatile organic compounds

Mesh:

Substances:

Year:  2017        PMID: 29089106     DOI: 10.1016/j.chroma.2017.10.062

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Evaluation of a novel hollow fiber membrane technique for collection of 1,1-dimethylhydrazine in air.

Authors:  Elnaz Taheri; Abdulrahman Bahrami; Farshid Ghorbani Shahna; Maryam Farhadian
Journal:  Environ Monit Assess       Date:  2018-07-20       Impact factor: 2.513

2.  Preparation of Carbotrap/silica composite for needle trap field sampling of halogenated volatile organic compounds followed by gas chromatography/mass spectrometry determination.

Authors:  Ali Poormohammadi; Abdulrahman Bahrami; Alireza Ghiasvand; Farshid Ghorbani Shahna; Maryam Farhadian
Journal:  J Environ Health Sci Eng       Date:  2019-12-05

Review 3.  Advances in pretreatment and analysis methods of aromatic hydrocarbons in soil.

Authors:  Na Song; Yonghui Tian; Zewei Luo; Jianxiong Dai; Yan Liu; Yixiang Duan
Journal:  RSC Adv       Date:  2022-02-21       Impact factor: 3.361

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.