Abstract

PURPOSE: A subluxation or dislocation of the intraocular lens (IOL) is a well-known complication after cataract surgery in patients with pseudoexfoliation syndrome (PEX). Capsular tension rings (CTR) are frequently used to prevent postoperative complications caused by zonular weakness. Here we present a series of 7 cases, 2 with intermittent and 5 with acute angle closure caused by a combination of PEX-associated zonular weakness and a resulting unstable capsular bag-CTR-IOL complex.
MATERIALS AND METHODS: We describe the typical clinical course with elevated intraocular pressure, myopic shift, and shallowing of the anterior chamber in 7 patients with a new type of secondary angle closure. The diagnostic challenges and treatment options are discussed in detail.
RESULTS: In all cases, the mechanism of angle closure identified by ultrasound biomicroscopy was an anterior dislocation of the peripheral iris by the capsular bag-CTR-IOL complex. The IOL was removed together with the capsular bag and the CTR and replaced by an iris-fixated IOL in all cases.
CONCLUSIONS: We present a new type of secondary angle closure caused by an anterior dislocated capsular bag-CTR-IOL complex. The cause of both, this atypical presentation and the ineffectiveness of the laser peripheral iridotomy is the large diameter CTR. Therefore CTR implantation might also be the source of late postoperative complications. If a secondary angle closure associated with PEX and unstable capsular bag-CTR-IOL complex is encountered, IOL explantation and replacement by an iris-fixated IOL is a simple and effective treatment option.

Entities:  

Mesh:

Year:  2017        PMID: 29077625     DOI: 10.1097/IJG.0000000000000780

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  3 in total

1.  Efficacy of haptic sutured in-the-bag intraocular lens for intraocular lens-capsule complex stability: a comparison of three insertion methods.

Authors:  Yang Kyung Cho; Andrew Thomson; Balamurali K Ambati
Journal:  Int J Ophthalmol       Date:  2022-09-18       Impact factor: 1.645

2.  Effect of capsular tension ring implantation on predicted refractive error after cataract surgery in patients with pseudoexfoliation syndrome.

Authors:  Mohammad Malekahmadi; Sadegh Kazemi; Farideh Sharifipour; Farshad Ostadian; Atefeh Mahdian Rad; Mohammad Sadegh Mirdehghan
Journal:  Int J Ophthalmol       Date:  2020-04-18       Impact factor: 1.779

3.  A Case of Repeating Transient Increase in Intraocular Pressure by Instability of an Intraocular Lens Implanted in the Capsular Bag.

Authors:  Yukihisa Takada; Takayoshi Sumioka; Nobuyuki Ishikawa; Shingo Yasuda; Ryoko Komori; Shizuya Saika
Journal:  Case Rep Ophthalmol       Date:  2020-01-29
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.