Literature DB >> 29077503

Radiographic Assessment of Lower-Limb Discrepancy.

Maria Reina-Bueno, Guillermo Lafuente-Sotillos, Jose M Castillo-Lopez, Estela Gomez-Aguilar, Pedro V Munuera-Martinez.   

Abstract

BACKGROUND: This study compares different lower-limb length measurements using tests of lower-limb upright full-length radiography and anteroposterior radiography of load-bearing hips.
METHODS: Forty-seven consecutive individuals aged 17 to 61 years (mean ± SD, 31.47 ± 11.42 years) voluntarily took part in the study; 23 (48.9%) were women and 24 (51.1%) were men. All individuals presenting a difference of 5 mm or greater between both lower limbs quantified with a tape measure were included. All of the participants signed an informed consent form to take part in the study. Two anteroposterior load-bearing radiographs were taken: one of the hip and an upright full-length radiograph of the lower limbs. Lower-limb-length discrepancy was quantified by taking different reference points. Interobserver and intraobserver reliability was assessed for each radiographic measurement. Any correlation between the different measurements were also verified.
RESULTS: Interobserver and intraobserver reliability was high for all of the measurements because the intraclass correlation was greater than 0.75 in all of the cases. There was a strong and positive correlation between the different measurements because when performing bivariate correlations with the Pearson correlation coefficient, positive values close to 1 were found.
CONCLUSIONS: In this study, the different reference points reported in the upright full-length radiograph in addition to the hip radiographs are useful for assessing lower-limb-length discrepancy. The results showed that there is a correct correlation between the different measurements.

Entities:  

Mesh:

Year:  2017        PMID: 29077503     DOI: 10.7547/15-204

Source DB:  PubMed          Journal:  J Am Podiatr Med Assoc        ISSN: 1930-8264


  2 in total

1.  Accuracy of biplanar linear radiography versus conventional radiographs when used for lower limb and implant measurements.

Authors:  Chen Xi Kasia Chua; Si Heng Sharon Tan; Andrew Kean Seng Lim; James Hoipo Hui
Journal:  Arch Orthop Trauma Surg       Date:  2021-01-02       Impact factor: 3.067

2.  Leg length discrepancy: A systematic review on the validity and reliability of clinical assessments and imaging diagnostics used in clinical practice.

Authors:  Martin Alfuth; Patrick Fichter; Axel Knicker
Journal:  PLoS One       Date:  2021-12-20       Impact factor: 3.240

  2 in total