Literature DB >> 29073809

Pregnancy and delivery with an intrauterine device in situ: outcomes in the National Inpatient Sample Database.

Sandy Fulkerson Schaeffer1, Alexis C Gimovsky2, Hany Aly3, Mohamed A Mohamed3.   

Abstract

BACKGROUND: Pregnancy with intrauterine device in place is rare and there are limited data that exist regarding associated perinatal outcomes.
OBJECTIVE: The objective of this study is to determine the association between presence of an intrauterine device during pregnancy and spontaneous abortion, induced abortion, and preterm or small for gestational age delivery outcomes. STUDY
DESIGN: The National Inpatient Sample database was analyzed for the years 2010 and 2011. Maternal records with an intrauterine device in situ during delivery were identified using International Classification of Diseases, Ninth Revision, diagnostic codes. Primary outcome was incidence of spontaneous abortion. Secondary outcomes were incidence of induced abortion, preterm delivery, and small for gestational age. Data were analyzed using Chi-square and Fisher's exact tests to calculate odds ratios (ORs) of abortion in association with intrauterine device in situ during pregnancy. Maternal birth records were further analyzed for adverse neonatal outcomes using logistic regression models, controlling for possible confounding variables.
RESULTS: The data included 8,597,284 maternal birth records; 0.02% with an intrauterine device in situ. Patients with an intrauterine device in situ experienced a higher frequency of the pregnancy ending in spontaneous abortion (OR: 7.15; 95% confidence interval (CI): 5.06-10.09; p < .001) and induced abortion (OR: 23.12; 95% CI: 15.55-34.36; p < .001) than patients without an intrauterine device in place. Adjusted odds ratio for preterm delivery among women with an intrauterine device in situ was 2.04 (95% CI: 1.71-2.43; p < .001) compared with women without an intrauterine device, and adjusted odds ratio for delivery of a small for gestational age infant among intrauterine device cohort was 0.56 (95% CI: 0.34-0.92; p = .022), after controlling for associated demographic and clinical variables.
CONCLUSION: The presence of an intrauterine device in situ during pregnancy was associated with increased spontaneous and induced abortions, and increased incidence of delivery of a preterm, but not small for gestational age infant.

Entities:  

Keywords:  Intrauterine device; pregnancy; preterm birth; spontaneous abortion

Mesh:

Year:  2017        PMID: 29073809     DOI: 10.1080/14767058.2017.1391783

Source DB:  PubMed          Journal:  J Matern Fetal Neonatal Med        ISSN: 1476-4954


  1 in total

1.  Predicting Risk of Perioperative Ischemic Optic Neuropathy in Spine Fusion Surgery: A Cohort Study Using the National Inpatient Sample.

Authors:  Shikhar H Shah; Yi-Fan Chen; Heather E Moss; Daniel S Rubin; Charlotte E Joslin; Steven Roth
Journal:  Anesth Analg       Date:  2020-04       Impact factor: 5.108

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.