Literature DB >> 29073485

Acoustic source localization in anisotropic plates with "Z" shaped sensor clusters.

Shenxin Yin1, Zhiwen Cui2, Tribikram Kundu3.   

Abstract

A new sensor cluster orientation is proposed to localize an acoustic source in a plate from the time difference of arrival (TDOA) with the help of only four to eight sensors. This technique requires neither a priori knowledge of the plate material properties nor a dense array of sensors to localize the acoustic source in isotropic as well as anisotropic plates. It is achieved by placing four sensors in a cluster in the shape of letter "Z" over a small region of the plate and a second Z-shaped cluster at another location of the plate. Experimental results show that it is possible to accurately localize the acoustic source with this new configuration. It reduces the number of sensors required for acoustic source localization in an anisotropic plate. Although one cluster in principle is capable of localizing the acoustic source in absence of any experimental error for accurate source localization in presence of experimental error two such Z-shaped clusters are needed. In the currently available technique three L-shaped clusters having a total of 9 sensors are needed to achieve the same level of confidence in the acoustic source localization. Thus, the proposed new technique reduces the number of sensors by 1 (from 9 to 8) for confidently and accurately predicting the acoustic source.
Copyright © 2017 Elsevier B.V. All rights reserved.

Keywords:  Acoustic emission; Acoustic source localization; Anisotropic plate; L-shaped clusters; Time difference of arrival

Year:  2017        PMID: 29073485     DOI: 10.1016/j.ultras.2017.10.007

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  2 in total

1.  A Weighted Linear Least Squares Location Method of an Acoustic Emission Source without Measuring Wave Velocity.

Authors:  Zilong Zhou; Yichao Rui; Xin Cai; Ruishan Cheng; Xueming Du; Jianyou Lu
Journal:  Sensors (Basel)       Date:  2020-06-04       Impact factor: 3.576

2.  Analysis of Errors in the Estimation of Impact Positions in Plate-Like Structure through the Triangulation Formula by Piezoelectric Sensors Monitoring.

Authors:  Eugenio Marino-Merlo; Andrea Bulletti; Pietro Giannelli; Marco Calzolai; Lorenzo Capineri
Journal:  Sensors (Basel)       Date:  2018-10-12       Impact factor: 3.576

  2 in total