Literature DB >> 29071436

Measurement and scan reproducibility of parameters of intravoxel incoherent motion in renal tumor and normal renal parenchyma: a preliminary research at 3.0 T MR.

Jingjing Pan1,2, Hongtao Zhang1,3, Fengyuan Man2, Yanguang Shen1, Yingwei Wang1, Yan Zhong1, Lu Ma1, Haiyi Wang4, Huiyi Ye5.   

Abstract

PURPOSE: To prospectively estimate measurement and scan reproducibility of parameters of intravoxel incoherent motion (IVIM) in renal tumors, normal renal cortex, and medulla.
METHODS: Twenty-four consecutive patients (twelve males and twelve females; median age 56.7 years, range 32-71 years) with 25 renal tumors (20 renal cell carcinomas, one urothelium carcinoma, three angiomyolipomas, and one oncocytoma) were examined twice using IVIM1 and IVIM2 with 9 and 16 b values, respectively, at 3.0 T. All the patients were re-scanned in 24-48 h. Regions of interest (ROIs) were placed in solid part of tumor, normal cortex, and medulla to derive IVIM parameters D (true diffusion coefficient), D* (pseudodiffusion coefficient), and f (perfusion fraction of pseudodiffusion). Differences in parameters between two IVIM sets and intra-observer, inter-observer, and scan-rescan differences were assessed using paired t tests. Intra-observer, inter-observer, and scan-rescan reproducibility were assessed by measuring coefficient of variation and Bland-Altman limits of agreements.
RESULTS: Intra-observer reproducibility of renal tumors, normal renal cortex, and medulla was excellent for apparent diffusion coefficient (ADC; CV: 3.45%-5.34%, BA-LA: -14% to 18%) and D (CV: 3.65% to 6.04%, BA-LA: -18% to 19%), good for f (CV: 11.96%-16.08%, BA-LA: -76.4% to 92.1% except f of medulla with CV of 32.59% and BA-LA of -76.4% to 92.1% in IVIM1), and poor for D* (CV: 25.0% to 75.4%, BA-LA: -111% to 150%). The same order was in inter-observer reproducibility analysis. Scan-rescan reproducibility was the worst of the three parameters. Renal medulla showed worse reproducibility than renal tumors and the normal cortex. The metrics of IVIM2 had better reproducibility than IVIM1.
CONCLUSION: Excellent reproducibility evaluation for ADC and D, good for f, and poor for D* derived from IVIM was performed in renal tumors, normal renal cortex, and medulla. D* has limited reliability and scan-rescan reproducibility should be improved.

Entities:  

Keywords:  Diffusion-weighted imaging, DWI; Intravoxel incoherent motion, IVIM; Magnetic resonance imaging, MRI; Renal tumors; Reproducibility

Mesh:

Year:  2018        PMID: 29071436     DOI: 10.1007/s00261-017-1361-7

Source DB:  PubMed          Journal:  Abdom Radiol (NY)


  7 in total

1.  Differentiating between malignant and benign renal tumors: do IVIM and diffusion kurtosis imaging perform better than DWI?

Authors:  Yuqin Ding; Qinxuan Tan; Wei Mao; Chenchen Dai; Xiaoyi Hu; Jun Hou; Mengsu Zeng; Jianjun Zhou
Journal:  Eur Radiol       Date:  2019-06-03       Impact factor: 5.315

2.  Quantitative assessment of renal allograft pathologic changes: comparisons of mono-exponential and bi-exponential models using diffusion-weighted imaging.

Authors:  Min Fan; Zhaoyu Xing; Yanan Du; Liang Pan; Yangyang Sun; Xiaozhou He
Journal:  Quant Imaging Med Surg       Date:  2020-06

3.  Whole-lesion ADC histogram analysis is not able to reflect microvessel density in HNSCC.

Authors:  Hans-Jonas Meyer; Gordian Hamerla; Leonard Leifels; Anne Kathrin Höhn; Alexey Surov
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

4.  Renal Diffusion-Weighted Imaging in Healthy Dogs: Reproducibility, Test-Retest Repeatability, and Selection of the Optimal b-value Combination.

Authors:  Sang-Kwon Lee; Juryeoung Lee; Seolyn Jang; Eunji Lee; Chang-Yeop Jeon; Kyung-Seoub Lim; Yeung Bae Jin; Jihye Choi
Journal:  Front Vet Sci       Date:  2021-07-02

Review 5.  Perfusion-driven Intravoxel Incoherent Motion (IVIM) MRI in Oncology: Applications, Challenges, and Future Trends.

Authors:  Mami Iima
Journal:  Magn Reson Med Sci       Date:  2020-06-15       Impact factor: 2.471

6.  Optimal acquisition scheme for flow-compensated intravoxel incoherent motion diffusion-weighted imaging in the abdomen: An accurate and precise clinically feasible protocol.

Authors:  Oliver J Gurney-Champion; Susanne S Rauh; Kevin Harrington; Uwe Oelfke; Frederik B Laun; Andreas Wetscherek
Journal:  Magn Reson Med       Date:  2019-09-30       Impact factor: 4.668

7.  Multiparametric Renal MRI: An Intrasubject Test-Retest Repeatability Study.

Authors:  Anneloes de Boer; Anita A Harteveld; Bjorn Stemkens; Peter J Blankestijn; Clemens Bos; Suzanne L Franklin; Martijn Froeling; Jaap A Joles; Marianne C Verhaar; Nico van den Berg; Hans Hoogduin; Tim Leiner
Journal:  J Magn Reson Imaging       Date:  2020-04-16       Impact factor: 4.813

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.